{"id":608,"date":"2019-06-01T11:54:52","date_gmt":"2019-06-01T11:54:52","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=608"},"modified":"2021-06-11T10:24:59","modified_gmt":"2021-06-11T08:24:59","slug":"diseno-eficiente-de-instalaciones-de-climatizacion","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2019\/06\/01\/diseno-eficiente-de-instalaciones-de-climatizacion\/","title":{"rendered":"Dise\u00f1o eficiente de instalaciones de climatizaci\u00f3n por Esteban Dom\u00ednguez Gonz\u00e1lez-Seco"},"content":{"rendered":"\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"924\" height=\"924\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban.jpg\" alt=\"\" class=\"wp-image-609 size-full\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban.jpg 924w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-150x150.jpg 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-300x300.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-768x768.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-500x500.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-800x800.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-160x160.jpg 160w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Esteban-320x320.jpg 320w\" sizes=\"(max-width: 924px) 100vw, 924px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"> <strong>Esteban Dom\u00ednguez Gonz\u00e1lez-Seco<\/strong><\/p>\n\n\n\n<p> Director T\u00e9cnico en Acix Consultor\u00eda T\u00e9cnica S.L.  (Profesor del Curso de Experto de Climatizaci\u00f3n de Atecyr y Socio Numerario N\u00ba 7521)<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>Cuando hablamos de dise\u00f1o eficiente de instalaciones r\u00e1pidamente nos vienen a la cabeza referencias a normativas y m\u00e9tricas que nos permiten objetivar las bondades, o realidades, de las instalaciones proyectadas y finalmente ejecutadas.<\/p>\n\n\n\n<p>Este marco normativo, cada vez\nm\u00e1s exigente, converge a un objetivo claro de acabar dise\u00f1ando, y\ndisfrutando,&nbsp; de edificios NZEB. El\nt\u00e9rmino NZEB, como todos conocemos ya, es un acr\u00f3nimo del ingl\u00e9s \u00abNearly\nZero Energy Building\u00bb, que puede traducirse como \u00abedificios de\nconsumo de energ\u00eda casi nulo\u00bb, &nbsp;y\nhace referencia a los edificios que cumplen con un nivel de eficiencia\nenerg\u00e9tica muy alto y un <a href=\"http:\/\/www.cenergetica.es\/casas-pasivas\">consumo de\nenerg\u00eda <\/a>muy bajo, que deber\u00e1 de proceder en su mayor\u00eda de fuentes\nrenovables (definido seg\u00fan Directiva 2010\/31\/EU). La pr\u00f3xima aprobaci\u00f3n del\nnuevo Documento B\u00e1sico HE del C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n de eficiencia\nenerg\u00e9tica volver\u00e1 a poner \u00e9nfasis en todos los puntos a cumplir por los\nproyectistas incrementando de forma significativa valores de control que\nconduzcan al objetivo. Conceptos como transmitancia global, ganancia solar,\nconsumo de energ\u00eda primaria, energ\u00eda primaria no renovable, etc. copar\u00e1n\nnuestra atenci\u00f3n y marcar\u00e1n en gran medida nuestros dise\u00f1os y quehacer en el\nsector.<\/p>\n\n\n\n<p>No obstante quer\u00eda reflexionar en\neste post sobre distintos puntos que de forma b\u00e1sica deber\u00edan marcar los\ndise\u00f1os eficientes de instalaciones de climatizaci\u00f3n y que muchas veces se\npueden perder o disolver entre la dial\u00e9ctica y normativa mencionada.<\/p>\n\n\n\n<p><strong>1.- Mon\u00f3tona de carga<\/strong>. Tan relevante, o m\u00e1s, como la demanda termo\nfrigor\u00edfica global y punta de la instalaci\u00f3n, es conocer de forma clara &nbsp;la curva de variaci\u00f3n anual del edificio a\nclimatizar. La tipolog\u00eda del edificio, sus condiciones de explotaci\u00f3n,\nubicaci\u00f3n geogr\u00e1fica, etc. nos llevar\u00e1n a necesidades muy variables a las que\ndebemos acoplar nuestra selecci\u00f3n de equipos tanto de producci\u00f3n como de\ndistribuci\u00f3n. Una mala selecci\u00f3n de estos equipos a cargas parciales limita, no\nsolo la eficiencia de la soluci\u00f3n proyectada, sino su&nbsp; vida \u00fatil.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"857\" height=\"488\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico.jpg\" alt=\"\" class=\"wp-image-610\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico.jpg 857w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-300x171.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-768x437.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-500x285.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-800x456.jpg 800w\" sizes=\"(max-width: 857px) 100vw, 857px\" \/><\/figure><\/div>\n\n\n\n<p><strong>2.- Adecuada selecci\u00f3n de equipos y componentes<\/strong>. El RITE ha puesto\ncierto \u00e9nfasis en la selecci\u00f3n de equipos de producci\u00f3n, dando ciertas pautas\npara su adecuado dimensionamiento. Vincular la selecci\u00f3n de enfriadoras\ncondensadas por aire a la temperatura seca del lugar con cierto margen (seg\u00fan\nla IT 1.2.4.1.3.3 se dimensionar\u00e1n a la temperatura seca exterior igual a la\ndel nivel percentil m\u00e1s exigente m\u00e1s 3 \u00baC) o la selecci\u00f3n de torres de\nrefrigeraci\u00f3n en condiciones adecuadas de operaci\u00f3n (seg\u00fan la IT 1.2.4.1.3.4 &nbsp;se dimensionar\u00e1n para el valor de la temperatura h\u00fameda que corresponde\nal nivel percentil m\u00e1s exigente m\u00e1s 1 \u00b0C) ya es algo interiorizado en el\ndise\u00f1o. Esta selecci\u00f3n, junto con el fuerte impulso de la Directiva de\nEcodise\u00f1o, instaurando en la Uni\u00f3n Europea un marco para el establecimiento de requisitos\nobligatorios de ecodise\u00f1o a los productos relacionados con la Energ\u00eda (ErP),\npermite afinar de forma definitiva la eficiencia de los equipos de producci\u00f3n,\nque si han sido bien seleccionados para la mon\u00f3tona de carga, permitir\u00e1n\nacercarnos mucho a los objetivos de eficiencia establecidos.<\/p>\n\n\n\n<p>No obstante hay otros puntos, sin\ntanta relevancia normativa, que es conveniente cuidar en el dise\u00f1o y que nos\npueden alejar de los consumos previstos:<\/p>\n\n\n\n<ul><li>El <strong>S\u00edndrome\nde bajo Delta T (\u2206T)<\/strong> ocasiona que se incremente la cantidad de equipos productores\ndebido al exceso de caudal circulante. Como sabemos se denomina Delta T a la\ndiferencia entre la temperatura de entrada y de salida en una bater\u00eda. Si el caudal\nde agua en la bater\u00eda es muy alto, esta no absorber\u00e1 el fr\u00edo o calor del aire\nde manera eficiente. Esto se debe a que a mayor caudal, el agua estar\u00e1 menos tiempo\ndentro de la bater\u00eda, provocando que no se realice la transferencia t\u00e9rmica de\nforma adecuada y que la temperatura de salida est\u00e9 por debajo de la temperatura\nde dise\u00f1o.<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"557\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-1024x557.jpg\" alt=\"\" class=\"wp-image-611\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-1024x557.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-300x163.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-768x418.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-500x272.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-800x435.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2-1280x696.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gr\u00e1fico-2.jpg 1296w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<p>Una adecuada selecci\u00f3n\nde la v\u00e1lvula de control, con exigencia de control a cargas parciales, y\ncombinada de forma adecuada con el comportamiento de la bater\u00eda limita este efecto. As\u00ed mismo una opci\u00f3n muy\nconveniente puede ser el empleo de v\u00e1lvulas independientes de la presi\u00f3n, que\npermiten regular y mantener el caudal constante en la bater\u00eda a medida que la\npresi\u00f3n var\u00eda dependiendo de la demanda. Esta caracter\u00edstica incrementa la\neficiencia energ\u00e9tica logrando mantener la instalaci\u00f3n en las condiciones\ndeseadas de operaci\u00f3n.<\/p>\n\n\n\n<ul><li><strong>Sistemas\nhidr\u00e1ulicos<\/strong>. Uno de los grandes consumidores de la instalaci\u00f3n de\nclimatizaci\u00f3n son los sistemas de distribuci\u00f3n hidr\u00e1ulicos cuyas condiciones de\ndise\u00f1o en muchos casos no vienen reguladas por la normativa vigente. As\u00ed por\nejemplo el RITE&nbsp; no &nbsp;define de forma clara un SPF para sistemas hidr\u00e1ulicos,\nni entra de forma profunda en el equilibrado de la red. La conveniencia de\nestablecer sistemas de &nbsp;caudal variable\nen funci\u00f3n del tipo de instalaci\u00f3n, las condiciones de regulaci\u00f3n de sistemas\nde bombeo,&nbsp; las condiciones de regulaci\u00f3n\n(fines de l\u00ednea, caudales m\u00ednimos, etc.) o los caudales m\u00e1ximos de dise\u00f1o por\ncalibre (velocidades m\u00e1ximas, dimensionado en funci\u00f3n de horas de\nfuncionamiento,&nbsp; etc.) no siempre est\u00e1n\npresentes en los dise\u00f1os a pesar de existir bibliograf\u00eda abundante sobre su\nconveniencia y relevancia en la eficiencia de la instalaci\u00f3n en su conjunto.<\/li><\/ul>\n\n\n\n<ul><li><strong>Dise\u00f1o de\nclimatizadores y sistemas de ventilaci\u00f3n. <\/strong>Al igual que en el dise\u00f1o de\nredes hidr\u00e1ulicas hay componentes de la red de aire cuyo estudio es primordial\npara la optimizaci\u00f3n de la eficiencia de la instalaci\u00f3n. La definici\u00f3n de forma\nadecuada de la estanqueidad de las &nbsp;compuertas de toma de aire y freecooling para\nevitar exceso de aire exterior o evitar variaciones importantes del caudal en\nel climatizador por ejemplo, pueden ser la explicaci\u00f3n de la perdida de la\neficiencia prevista en el dise\u00f1o inicial.<\/li><\/ul>\n\n\n\n<p><strong>3.- Ausencia de lazos de control\/memoria de control adecuada. <\/strong>La\nm\u00e1xima de que \u201cla potencia sin control no sirve de nada\u201d est\u00e1 muy interiorizada\nen el mundo de la ingenier\u00eda pero sin embargo es uno de los caballos de batalla\nen la explotaci\u00f3n de las instalaciones de climatizaci\u00f3n. Elementos clave en la\ninstalaci\u00f3n como disponer en caudal variable de una adecuada relaci\u00f3n entre el\ncaudal primario y secundario, que permita mantener la temperatura de impulsi\u00f3n\ny salto t\u00e9rmico constante, o garantizar la presi\u00f3n diferencial disponible no se\ncuidan con toda la relevancia que se debiera en la explotaci\u00f3n de la\ninstalaci\u00f3n, observ\u00e1ndose fuertes derivas entre la eficiencia prevista y la\nobtenida.<\/p>\n\n\n\n<p>Con todo lo expuesto de manera\nsomera solo se pretende reflexionar,&nbsp; que\ndetr\u00e1s de cada m\u00e9trica, y de cada valor introducido en un programa de caculo o\ncertificaci\u00f3n, hay labores de dise\u00f1o en m\u00faltiples \u00e1mbitos, &nbsp;que permitir\u00e1n alcanzar el objetivo no solo de\nmanera virtual sino en una explotaci\u00f3n real, si se abordan con antelaci\u00f3n y\nadecuada planificaci\u00f3n.<\/p>\n\n\n\n<p><strong>BIBLIOGRAFIA<\/strong><\/p>\n\n\n\n<ul><li>&nbsp;DIRECTIVA 2010\/31\/UE DEL PARLAMENTO EUROPEO Y\nDEL CONSEJO de 19 de mayo de 2010 relativa a la eficiencia energ\u00e9tica de los\nedificios.<\/li><li>DIRECTIVA\n(UE) 2018\/844 DEL PARLAMENTO EUROPEO Y DEL CONSEJO de 30 de mayo de 2018 por la\nque se modifica la Directiva 2010\/31\/UE relativa a la eficiencia energ\u00e9tica de\nlos edificios y la Directiva 2012\/27\/UE relativa a la eficiencia energ\u00e9tica.<\/li><li>Real\nDecreto 1027\/2007, de 20 de julio, por el que se aprueba el Reglamento de\nInstalaciones T\u00e9rmicas en los Edificios.<\/li><li><a href=\"http:\/\/www.boe.es\/boe\/dias\/2013\/04\/13\/pdfs\/BOE-A-2013-3905.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Real Decreto 238\/2013<\/a>, de\n5 de abril, por el que se modifican determinados art\u00edculos e instrucciones\nt\u00e9cnicas del Reglamento de Instalaciones T\u00e9rmicas en los Edificios, aprobado\npor el Real Decreto 1027\/2007, de 20 de julio (conocido en la pr\u00e1ctica por su\nacr\u00f3nimo RITE).<\/li><li>DTIE 9.07\nC\u00c1LCULO Y SELECCI\u00d3N DE EQUIPOS PRIMARIOS<\/li><li>DTIE 9.06 SELECCI\u00d3N DE EQUIPOS SECUNDARIOS SEG\u00daN EL SISTEMA<\/li><li>Est\u00e1ndar ANSI\/ASHRAE\/IES 90.1-2016 \u201cEnergy Efficiency Standard for\nBuildings Except Low-Rise Residential Buildings\u00bb<\/li><li>2017 ASHRAE\nHandbook\u2014Fundamentals<\/li><li>2016 ASHRAE Handbook\u2014HVAC\nSystems and Equipment<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Esteban Dom\u00ednguez Gonz\u00e1lez-Seco Director T\u00e9cnico en Acix Consultor\u00eda T\u00e9cnica S.L. (Profesor del Curso de Experto de Climatizaci\u00f3n de Atecyr y Socio Numerario N\u00ba 7521) Cuando hablamos de dise\u00f1o eficiente de instalaciones r\u00e1pidamente nos vienen&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":1394,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[5],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/608"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":6,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/608\/revisions"}],"predecessor-version":[{"id":2040,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/608\/revisions\/2040"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/1394"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=608"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=608"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}