{"id":603,"date":"2019-06-01T11:39:37","date_gmt":"2019-06-01T11:39:37","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=603"},"modified":"2021-06-11T10:25:34","modified_gmt":"2021-06-11T08:25:34","slug":"eficiencia-energetica-en-instalaciones-de-agua-caliente-sanitaria-la-importancia-del-sistema-de-acumulacion","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2019\/06\/01\/eficiencia-energetica-en-instalaciones-de-agua-caliente-sanitaria-la-importancia-del-sistema-de-acumulacion\/","title":{"rendered":"Eficiencia energ\u00e9tica en instalaciones de agua caliente sanitaria. La importancia del sistema de acumulaci\u00f3n por Gaspar Mart\u00edn S\u00e1nchez"},"content":{"rendered":"\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"923\" height=\"917\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn.jpg\" alt=\"\" class=\"wp-image-604 size-full\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn.jpg 923w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn-150x150.jpg 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn-300x298.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn-768x763.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn-500x497.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn-800x795.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/Gaspar-Mart\u00edn-160x160.jpg 160w\" sizes=\"(max-width: 923px) 100vw, 923px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"><strong>Gaspar Mart\u00edn S\u00e1nchez<\/strong><\/p>\n\n\n\n<p>Director T\u00e9cnico Groupe Atlantic (ACV, Socio protector de Atecyr)<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>INTRODUCCI\u00d3N<\/strong><\/p>\n\n\n\n<p>Dentro de una estrategia de gesti\u00f3n\nenerg\u00e9tica eficiente de las instalaciones (sean del tipo que sean), una\nvariable fundamental es plantear el uso de sistemas y tecnolog\u00edas lo m\u00e1s\neficientes posibles para satisfacer las demandas solicitadas utilizando el\nm\u00ednimo de energ\u00eda.<\/p>\n\n\n\n<p>Ya las diversas Directivas Europeas\nvan en esta direcci\u00f3n desde hace unos a\u00f1os, promoviendo el uso de energ\u00edas\nrenovables con el objetivo de alcanzar los edificios nZEB, o marcando el camino\na los fabricantes de aquellos productos que podemos comercializar (con el enfoque\nde la reducci\u00f3n de emisiones de gases contaminantes para la consecuci\u00f3n de los\ndiversos compromisos medioambientales). En este sentido la Directiva de Ecodise\u00f1o\nErP, de aplicaci\u00f3n desde el 26 de septiembre del 2015 y que afecta a los\nproductos relacionados con la energ\u00eda (calderas, bombas de calor, calentadores,\ndep\u00f3sitos de agua caliente, etc&#8230;), supuso un cambio importante en cuanto al\nsalto tecnol\u00f3gico y de eficiencia de los productos afectados. Como ejemplo, el\nrendimiento m\u00ednimo exigido para las calderas de gas, supone que la \u00fanica tecnolog\u00eda\nque puede alcanzarlo es la de condensaci\u00f3n.<\/p>\n\n\n\n<p><strong>EFICIENCIA EN INSTALACIONES DE PRODUCCI\u00d3N DE AGUA CALIENTE SANITARIA<\/strong><\/p>\n\n\n\n<p>Cuando se plantea una instalaci\u00f3n\nde tipo t\u00e9rmico para satisfacer una demanda de calefacci\u00f3n y agua caliente\nsanitaria, normalmente nos centramos m\u00e1s en optimizar la parte de calefacci\u00f3n\n(que generalmente es la que m\u00e1s carga t\u00e9rmica solicita), dejando en segundo\nplano la parte de A.C.S. No obstante tenemos que tener en consideraci\u00f3n que,\ndependiendo del tipo de instalaci\u00f3n, el consumo energ\u00e9tico que se destina para\nla demanda de A.C.S. puede llegar a ser el 30% de la factura energ\u00e9tica total\n(como pasa en tipolog\u00edas de obras grandes consumidoras de agua caliente como\nson los hoteles, gimnasios, hospitales, etc\u2026).<\/p>\n\n\n\n<p>Si nos centramos en la parte de\nla instalaci\u00f3n de A.C.S., su eficiencia estacional viene dada principalmente\nper cuanto de eficiente es el generador utilizado (en el mercado existen incluso\nlos generadores HEAT MASTER TC que pueden trabajar en curva de condensaci\u00f3n en\ncontinuo para producir A.C.S.), cuanto de eficiente es el sistema de intercambio\nutilizado (hablando exclusivamente en t\u00e9rminos energ\u00e9ticos siempre ser\u00e1 mejor\nutilizar un sistema interacumulador), y cuanto de eficiente es el sistema de acumulaci\u00f3n\nutilizado (elemento al que muchas veces no se le da la transcendencia que tiene\nen este tipo de instalaciones).<\/p>\n\n\n\n<p>Hablando de dep\u00f3sitos\nacumuladores, siempre partiendo de la premisa que han de ser suficientes para\nasegurar el consumo de agua caliente en los per\u00edodos puntas junto con las\ncalderas seleccionadas, se deber\u00eda intentar reducir al m\u00e1ximo su volumen as\u00ed\ncomo trabajar con acumuladores correctamente aislados, con el fin de reducir el\nconsumo energ\u00e9tico de este elemento.<\/p>\n\n\n\n<p><strong>DIRECTIVA DE ECODISE\u00d1O DE APLICACI\u00d3N EN DEPOSITOS ACUMULADORES DE A.C.S.<\/strong><\/p>\n\n\n\n<p>Ya se ha comentado anteriormente\nde la importancia en el sector de la Directiva de Ecodise\u00f1o ErP 2009\/125\/CE, y\nla Directiva complementaria de Etiquetado ELD 2010\/30\/UE (sustituida por el\nReglamento (UE) 2017\/1369), en cuanto a los requisitos de eficiencia que tienen\nque cumplir los productos relacionados con la energ\u00eda.&nbsp; El hecho m\u00e1s notable fue el cambio de tecnolog\u00edas\nen los equipos generadores debido a los rendimientos solicitados, afectando\nnotablemente al sector de las bombas de calor y calderas (recordando que en\ngas, la \u00fanica tecnolog\u00eda posible es la condensaci\u00f3n).<\/p>\n\n\n\n<p>En relaci\u00f3n a los dep\u00f3sitos de acumulaci\u00f3n de agua caliente, desde septiembre de 2015 los fabricantes tenemos que informar del valor de p\u00e9rdidas de energ\u00eda constantes de los mismos, para acumuladores de hasta 2.000 litros (seg\u00fan indica el Reglamento Delegado (UE) N\u00ba 814\/2013, de aplicaci\u00f3n para los productos de uso exclusivo para agua caliente sanitaria dentro del Lote 2). Este valor de p\u00e9rdidas energ\u00e9ticas se indica en la ficha del producto, y adicionalmente para el caso de acumuladores de tipo dom\u00e9stico (por debajo de 500 litros), se refleja tambi\u00e9n en la etiqueta energ\u00e9tica del producto seg\u00fan Reglamento Delegado (UE) N\u00ba 812\/2013. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"371\" height=\"707\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/etiqueta.jpg\" alt=\"\" class=\"wp-image-605\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/etiqueta.jpg 371w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/etiqueta-157x300.jpg 157w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/etiqueta-262x500.jpg 262w\" sizes=\"(max-width: 371px) 100vw, 371px\" \/><\/figure><\/div>\n\n\n\n<p>En la etiqueta, adem\u00e1s del valor\nde p\u00e9rdidas en W y el volumen en litros del acumulador, tambi\u00e9n aparece una\nescala gr\u00e1fica en colores y letras que indica la clase de eficiencia energ\u00e9tica\ndel acumulador en base a los rangos admisibles seg\u00fan la tabla incluida dentro\ndel art\u00edculo.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\n  Clase de eficiencia energ\u00e9tica \n  <\/td><td>\n  P\u00e9rdida est\u00e1tica <em>S <\/em>en vatios, con capacidad <em>V <\/em>en litros \n  <\/td><\/tr><tr><td>\n  A+\n  <\/td><td>\n  S &lt; 5,5 + 3,16 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  A\n  <\/td><td>\n  5,5 + 3,16 \u00b7 V <sup>0,4<\/sup>&nbsp; \u2264 S\n  &lt;&nbsp; 8,5 + 4,25 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  B\n  <\/td><td>\n  8,5 + 4,25 \u00b7 V <sup>0,4<\/sup>&nbsp; \u2264 S\n  &lt;&nbsp; 12 + 5,93 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  C\n  <\/td><td>\n  12 + 5,93 \u00b7 V <sup>0,4<\/sup>&nbsp; \u2264 S\n  &lt;&nbsp; 16,66 + 8,33 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  D\n  <\/td><td>\n  16,66 + 8,33 \u00b7 V <sup>0,4<\/sup> \u2264 S &lt;&nbsp; 21 + 10,33 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  E\n  <\/td><td>\n  21 + 10,33 \u00b7 V <sup>0,4<\/sup>&nbsp; \u2264 S\n  &lt;&nbsp; 26 + 13,66 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  F\n  <\/td><td>\n  26 + 13,66 \u00b7 V <sup>0,4<\/sup>&nbsp; \u2264 S\n  &lt;&nbsp; 31 + 16,66 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><tr><td>\n  G\n  <\/td><td>\n  S &gt; 31 + 16,66 \u00b7 V <sup>0,4<\/sup>\n  <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Desde septiembre de 2017 se tiene\nque cumplir un criterio de p\u00e9rdidas est\u00e1ticas m\u00e1ximas admisibles para el acumulador,\nexpresadas en W y calculadas a partir de la f\u00f3rmula 16,66 + 8,33\u00b7V <sup>0,4<\/sup>.\nSi no se cumple este requisito, el acumulador no puede conseguir el marcado CE\ny no puede comercializarse dentro de la Uni\u00f3n Europea. <\/p>\n\n\n\n<p>Este cambio normativo es muy transcendente\ndentro del mercado de los acumuladores de A.C.S. de hasta 2.000 litros. El\ncriterio de p\u00e9rdidas est\u00e1ticas m\u00e1ximas admisibles supone un cambio substancial\nen cuanto el tipo de aislamientos utilizados en los acumuladores, produci\u00e9ndose\nun salto cualitativo muy interesante en este aspecto. A nivel de dise\u00f1o supone\nla utilizaci\u00f3n de aislamientos, principalmente de poliuretano de alta densidad,\ny ser muy estricto en aislar adecuadamente las conexiones (para evitar puentes\nt\u00e9rmicos que provoquen una p\u00e9rdida energ\u00e9tica). <\/p>\n\n\n\n<p>Dentro del rango de acumuladores\nde hasta 500 litros (donde tamb\u00e9 aplica la Directiva de Etiquetado ELD), supone\nque la clase de eficiencia energ\u00e9tica m\u00ednima para estos tendr\u00e1 que ser C.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"383\" height=\"388\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/acumuladores.jpg\" alt=\"\" class=\"wp-image-606\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/acumuladores.jpg 383w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/06\/acumuladores-296x300.jpg 296w\" sizes=\"(max-width: 383px) 100vw, 383px\" \/><\/figure><\/div>\n\n\n\n<p><strong>CONCLUSIONES<\/strong><\/p>\n\n\n\n<p>Es evidente que las calderas\nutilizadas en una instalaci\u00f3n de A.C.S. tienen un peso importante en la eficiencia\nglobal de esta tipolog\u00eda de instalaciones. Hay que decir no obstante, debido a\nla homogeneizaci\u00f3n que ha supuesto la deriva hacia la condensaci\u00f3n en\ninstalaciones de gas debido al requisito de rendimiento m\u00ednimo seg\u00fan ErP (a no\nser que utilicemos sistemas diferenciales como son los generadores HEAT MASTER\nTC que pueden trabajar en curva continua de condensaci\u00f3n para producir A.C.S.),\nque el componente que m\u00e1s puede influir en una mejora significativa del rendimiento\nglobal de la instalaci\u00f3n es el sistema de acumulaci\u00f3n utilizado. Es fundamental\ndimensionar correctamente las demandas durante el per\u00edodo de consumo punta (para\nreducir lo m\u00e1ximo posible el volumen de agua acumulada y de esta manera reducir\nla energ\u00eda necesaria para mantener el agua a temperatura de trabajo), y utilizar\nacumuladores perfectamente aislados (la Directiva ErP pone orden en este\nsentido).<\/p>\n\n\n\n<p>El peso relativo dentro de la\nfactura energ\u00e9tica global del consumo para A.C.S. ir\u00e1 ganando importancia, m\u00e1s cuando\nla tendencia que marcar\u00e1 el futuro CTE en su DB-HE (con la definici\u00f3n nZEB de edificios\nde consumo de energ\u00eda casi cero), ser\u00e1 reducir significativamente\nla demanda de energ\u00eda necesaria para calefacci\u00f3n y refrigeraci\u00f3n. En este sentido,\nmejorar la eficiencia en la producci\u00f3n de A.C.S. en aquellas tipolog\u00edas de obra\ngrandes consumidoras de agua caliente ser\u00e1 fundamental, m\u00e1s cuando los est\u00e1ndares\nde confort en este tipo de consumos van en aumento. <\/p>\n\n\n\n<p>ACV es especialista desde 1922 en\nla fabricaci\u00f3n de equipos compactos y eficientes para instalaciones de\nproducci\u00f3n de A.C.S., tanto a nivel de generadores como de sistemas de acumulaci\u00f3n.\nSiempre comprometidos con el aseguramiento de las prestaciones y la m\u00e1xima eficiencia\nde esta tipolog\u00eda de instalaciones, se han propuesto al mercado las tecnolog\u00edas\nde acumulaci\u00f3n doble tanque (que permiten reducir hasta a un 60% las\nacumulaciones necesarias para asegurar las puntas de consumo en comparaci\u00f3n con\nacumuladores de gran volumen), con una tecnolog\u00eda en aislamientos lo m\u00e1s avanzada\nposible. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Gaspar Mart\u00edn S\u00e1nchez Director T\u00e9cnico Groupe Atlantic (ACV, Socio protector de Atecyr) INTRODUCCI\u00d3N Dentro de una estrategia de gesti\u00f3n energ\u00e9tica eficiente de las instalaciones (sean del tipo que sean), una variable fundamental es plantear&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":1377,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[5],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/603"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=603"}],"version-history":[{"count":7,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/603\/revisions"}],"predecessor-version":[{"id":2041,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/603\/revisions\/2041"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/1377"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=603"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=603"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}