{"id":2978,"date":"2025-03-13T11:53:54","date_gmt":"2025-03-13T10:53:54","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=2978"},"modified":"2025-03-19T09:15:04","modified_gmt":"2025-03-19T08:15:04","slug":"legionella-iii-regulacion-y-adecuacion-de-las-instalaciones-existentes-de-acs-por-ricardo-garcia-san-jose","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2025\/03\/13\/legionella-iii-regulacion-y-adecuacion-de-las-instalaciones-existentes-de-acs-por-ricardo-garcia-san-jose\/","title":{"rendered":"LEGIONELLA III: Regulaci\u00f3n y adecuaci\u00f3n de las instalaciones existentes de ACS por Ricardo Garc\u00eda San Jos\u00e9"},"content":{"rendered":"\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"923\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ.png\" alt=\"\" class=\"wp-image-1057 size-full\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ.png 925w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-150x150.png 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-300x300.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-768x766.png 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-500x500.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-800x798.png 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-160x160.png 160w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-320x320.png 320w\" sizes=\"(max-width: 925px) 100vw, 925px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"><strong>Ricardo Garc\u00eda San Jos\u00e9<\/strong><\/p>\n\n\n\n<p>Vicepresidente del Comit\u00e9 T\u00e9cnico de Atecyr<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>INTRODUCCI\u00d3N<\/strong><\/p>\n\n\n\n<p>La prevenci\u00f3n de la legionelosis en instalaciones de Agua Caliente Sanitaria (ACS) es un tema de vital importancia para la salud p\u00fablica que debe compaginarse con la eficiencia energ\u00e9tica.<\/p>\n\n\n\n<p>El Real Decreto 487\/2022 y sus modificaciones mediante el RD 614\/2024, han incluido unos requisitos sanitarios para el dise\u00f1o, mantenimiento y operaci\u00f3n de estas instalaciones que imponen unas variaciones importantes respecto a los utilizados con la aplicaci\u00f3n del RD 865\/2003.<\/p>\n\n\n\n<p>Este \u00faltimo post contin\u00faa con el an\u00e1lisis iniciado en los dos anteriores, en los que se han explorado los cambios normativos y las exigencias para la producci\u00f3n centralizada de ACS conforme a los mencionados Reales Decretos.<\/p>\n\n\n\n<p><strong>3.- REGULACI\u00d3N DE LA TEMPERATURA DE DISTRIBUCI\u00d3N<\/strong><\/p>\n\n\n\n<p>En todos los esquemas analizados se tienen producciones de al menos 60\u00baC que es conveniente reducir antes de su distribuci\u00f3n a consumo, asegurando los 50\u00baC en el punto m\u00e1s alejado; con la p\u00e9rdida de temperatura m\u00e1xima de 3\u00baC fijada en el punto 4.4.2. del HS4 la temperatura de distribuci\u00f3n puede mantenerse en 53\u00baC.<\/p>\n\n\n\n<p>Para ello hay dos formas habituales (Figura 14):<\/p>\n\n\n\n<ul>\n<li>Con v\u00e1lvulas motorizadas de tres v\u00edas controladas por una sonda de temperatura en impulsi\u00f3n.<\/li>\n\n\n\n<li>Con v\u00e1lvulas termost\u00e1ticas de cuatro v\u00edas, en las que se fija la consigna de distribuci\u00f3n.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"476\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-1024x476.jpg\" alt=\"\" class=\"wp-image-2979\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-1024x476.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-300x140.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-768x357.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-1536x715.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-2048x953.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-500x233.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-800x372.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-1280x596.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-14-1920x893.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 14<\/strong>: Regulaci\u00f3n de la temperatura de distribuci\u00f3n con v\u00e1lvula motorizada de tres v\u00edas y con termost\u00e1tica de cuatro v\u00edas.<\/p>\n\n\n\n<p>La recirculaci\u00f3n se conecta a la conexi\u00f3n del agua fr\u00eda, en el caso de la v\u00e1lvula motorizada de tres v\u00edas, o a la cuarta v\u00eda de la v\u00e1lvula termost\u00e1tica que est\u00e1 dise\u00f1ada para este cometido.<\/p>\n\n\n\n<p>El objetivo de esta conexi\u00f3n es mantener activada permanentemente la v\u00e1lvula de manera que se asegure una r\u00e1pida respuesta ante las variaciones de consumo.<\/p>\n\n\n\n<p>En las producciones con acumulaci\u00f3n cumple adem\u00e1s la funci\u00f3n de reducir la desestratificaci\u00f3n en los dep\u00f3sitos, ya que de ellos se toma solo el caudal necesario para compensar las p\u00e9rdidas de calor en la recirculaci\u00f3n, retorn\u00e1ndose directamente a consumo un porcentaje importante del caudal de recirculaci\u00f3n; por este motivo en la redacci\u00f3n del RD 487\/2022 se prohibi\u00f3 esta conexi\u00f3n. Sin embargo, al ser necesario para el correcto funcionamiento de los sistemas se ha eliminado la prohibici\u00f3n en las modificaciones del RD 614\/2024, realmente al poco tiempo de funcionamiento el agua de recirculaci\u00f3n acabar\u00e1 pasando por el interior de los dep\u00f3sitos.<\/p>\n\n\n\n<p><strong>4.- DISTRIBUCIONES INTERIORES<\/strong><\/p>\n\n\n\n<p>En las distribuciones se deben contemplar cuatro aspectos fundamentales:<\/p>\n\n\n\n<ul>\n<li><strong>Materiales<\/strong>: deben ser apropiados para el agua de consumo y adem\u00e1s soportar las condiciones de presi\u00f3n, temperatura y capaces para resistir las condiciones de las desinfecciones.<\/li>\n\n\n\n<li><strong>Retenci\u00f3n<\/strong>: Deben existir las v\u00e1lvulas de retenci\u00f3n suficientes para que el agua nunca pueda retornar, siendo necesarias tambi\u00e9n en los pies de montante.<\/li>\n\n\n\n<li><strong>Vaciados<\/strong>: Las instalaciones deben poder vaciarse totalmente para lo que se dispondr\u00e1n vaciados en los puntos bajos.<\/li>\n\n\n\n<li><strong>Equilibrado de la recirculaci\u00f3n<\/strong>: La temperatura m\u00ednima de 50\u00baC debe asegurarse en todos los puntos, lo que obliga a equilibrar los ramales de recirculaci\u00f3n, lo que puede lograrse con v\u00e1lvulas de equilibrado, retorno invertido u otros medios. Es conveniente colocar al menos term\u00f3metros en las derivaciones para poder comprobar de manera r\u00e1pida el estado de funcionamiento de las instalaciones.<\/li>\n\n\n\n<li><strong>Aislamiento T\u00e9rmico<\/strong>: Adem\u00e1s de por eficiencia energ\u00e9tica el aislamiento es imprescindible para lograr un adecuado mantenimiento de las temperaturas, cobra especial importancia aislar incluso las tuber\u00edas de agua fr\u00eda, sobre todo en las distribuciones que discurren en paralelo con las de ACS u otros servicios de calor.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"541\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-1024x541.jpg\" alt=\"\" class=\"wp-image-2980\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-1024x541.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-300x159.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-768x406.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-1536x812.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-2048x1082.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-500x264.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-800x423.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-1280x676.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-15-1920x1015.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 15<\/strong>: Detalles de las montantes de distribuci\u00f3n de ACS y recirculaci\u00f3n.<\/p>\n\n\n\n<p>Es muy importante comprobar que en los cuartos h\u00famedos los ramales sin recirculaci\u00f3n son inferiores a 5 m, o contienen menos de 3 L.<strong><br><\/strong><\/p>\n\n\n\n<p><a><strong>5.- INSTALACIONES EXISTENTES<\/strong><\/a><\/p>\n\n\n\n<p>Como se ha indicado en la introducci\u00f3n en la Disposici\u00f3n Transitoria cuarta se exige que las instalaciones existentes se adecuen a las exigencias del RD 487, lo que obliga a intervenciones muy importantes.<\/p>\n\n\n\n<ul>\n<li><strong>Dep\u00f3sitos<\/strong>: Si se confirma que los dep\u00f3sitos finales deben mantener permanentemente 60\u00baC se necesitan como m\u00ednimo dos dep\u00f3sitos, en nuevas instalaciones no es mayor problema, pero en las instalaciones existentes con un \u00fanico dep\u00f3sito se deber\u00eda modificar completamente la producci\u00f3n.<\/li>\n<\/ul>\n\n\n\n<p>Si los dep\u00f3sitos existentes no disponen de registros adecuados, de 400 mm para capacidades iguales o superiores a 750 L y conforme a la norma UNE EN 12897 para los de capacidad inferior desde 250 L, los mismos deber\u00edan cambiarse.<\/p>\n\n\n\n<ul>\n<li><strong>Producciones Instant\u00e1neas<\/strong>: Se deben regular para temperaturas de producci\u00f3n de 60\u00baC, si esto no fuese posible deber\u00edan sustituirse.<\/li>\n\n\n\n<li><strong>Materiales<\/strong>: Deber\u00e1n modificarse las instalaciones cuyos materiales no sean adecuados a las condiciones de temperatura y desinfecciones.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"350\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16-1024x350.jpg\" alt=\"\" class=\"wp-image-2981\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16-1024x350.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16-300x102.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16-768x262.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16-500x171.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16-800x273.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-16.jpg 1083w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul>\n<li><strong>Tomas de Muestras<\/strong>: en todas las instalaciones deben existir los puntos preparados para las tomas de muestras, debiendo realizarse los mismos sino existiesen; en ACS como m\u00ednimo se tendr\u00e1n en los dep\u00f3sitos y en la recirculaci\u00f3n.<\/li>\n\n\n\n<li><strong>Vaciados<\/strong>: Deber\u00e1n instalarse vaciados en todos los trazados que no dispongan de los mismos, intervenci\u00f3n que puede incluso obligar a modificarlos.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"338\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-1024x338.jpg\" alt=\"\" class=\"wp-image-2982\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-1024x338.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-300x99.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-768x254.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-1536x507.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-2048x676.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-500x165.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-800x264.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-1280x423.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/03\/Figura-17-1920x634.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul>\n<li><strong>V\u00e1lvulas de Retenci\u00f3n<\/strong>: Deben instalarse v\u00e1lvulas de retenci\u00f3n en aquellos puntos donde siendo necesarias no existan.<\/li>\n\n\n\n<li><strong>Recirculaciones interiores en cuartos h\u00famedos<\/strong>: En los locales donde se tengan distancias sin recirculaci\u00f3n superiores a 5 m, o cuyo contenido de agua de las tuber\u00edas sea superior a 3litros, deber\u00e1n conectarse recirculaciones por su interior con las generales.<\/li>\n\n\n\n<li><strong>Aislamiento T\u00e9rmico<\/strong>: Un problema muy extendido en las instalaciones de ACS es la falta de aislamiento o los espesores inadecuados del mismo; se deben aislar correctamente todas las instalaciones accesibles.<\/li>\n<\/ul>\n\n\n\n<p><strong>6.- PLAN DE PREVENCI\u00d3N Y CONTROL DE LEGIONELLA (PPCL)<\/strong><\/p>\n\n\n\n<p>Con fecha 02\/01\/2024 todos los edificios deber\u00edan haber realizado el PPCL de sus instalaciones con riesgo de proliferaci\u00f3n de Legionella, estos planes deben actualizarse a las modificaciones del RD 614\/2024 a m\u00e1s tardar el 01\/07\/2025.<\/p>\n\n\n\n<p>Los planes contendr\u00e1n al menos los siguientes aspectos:<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\">\n<li>Diagn\u00f3stico inicial, con datos t\u00e9cnicos, planos actualizados, puntos de toma de muestras y puntos de posible emisi\u00f3n de aerosoles.<\/li>\n\n\n\n<li>Descripci\u00f3n de los programas:<\/li>\n\n\n\n<li>Mantenimiento y revisi\u00f3n de las instalaciones<\/li>\n\n\n\n<li>Tratamiento, limpieza y desinfecci\u00f3n<\/li>\n\n\n\n<li>Muestreo<\/li>\n\n\n\n<li>Formaci\u00f3n del personal<\/li>\n\n\n\n<li>Documentaci\u00f3n y registros<\/li>\n<\/ol>\n\n\n\n<p>En los edificios que prestan servicios o son frecuentados por personas de especial vulnerabilidad (centros sanitarios, personas mayores, etc.) debe realizarse, con las mismas fechas, un Plan Sanitario frente a Legionella (<strong>PSL<\/strong>) que estar\u00e1 basado en una evaluaci\u00f3n de riesgos.<\/p>\n\n\n\n<p>Como consecuencia de estos planes se deben determinar las reformas m\u00ednimas a realizar en las instalaciones existentes, se pueden tomar como referencia las indicadas en el apartado anterior.<\/p>\n\n\n\n<p>El seguimiento de las instalaciones con los an\u00e1lisis de las muestras servir\u00e1 para corroborar que, aunque la instalaci\u00f3n existente no se ajuste estrictamente a las prescripciones del RD, si las ufc est\u00e1n en el intervalo admitido la instalaci\u00f3n puede considerarse segura no requiriendo modificaciones dr\u00e1sticas; evidentemente si se detectan valores elevados se deber\u00e1n afrontar estas reformas, incluso si suponen su total modificaci\u00f3n.<\/p>\n\n\n\n<p><strong>CONCLUSIONES Y COMENTARIOS<\/strong><\/p>\n\n\n\n<p>Las prescripciones del RD 487\/2022 y sus modificaciones RD 614\/2024, suponen un avance importante en la mejora de las instalaciones desde el punto de vista de seguridad sanitaria, por lo que es muy importante su cumplimiento.<\/p>\n\n\n\n<p>Si bien como todos los reglamentos junto a sus bondades tienen algunos aspectos que deben ser debatidos y, si fuese necesario, modificados.<\/p>\n\n\n\n<p>La producci\u00f3n de ACS con un m\u00ednimo de dos dep\u00f3sitos aporta mayor seguridad tanto sanitaria como de calidad de servicio, pero es preciso aclarar si la obligaci\u00f3n de mantener la temperatura de 60\u00baC es permanente o, garantizando que antes de distribuirse est\u00e1 a esos 60\u00baC, se admite que en las puntas de consumo en la parte media\/inferior de los dep\u00f3sitos finales se tienen temperaturas menores.<\/p>\n\n\n\n<p>Esta situaci\u00f3n se presentar\u00eda muy poco tiempo cada d\u00eda (habitualmente menos de una hora) permaneciendo las restantes horas a alta temperatura, por lo que el incremento del riesgo de proliferaci\u00f3n de Legionella ser\u00eda m\u00ednimo.<\/p>\n\n\n\n<p>En este sentido ser\u00eda conveniente que cuando se tengan casos de Legionelosis se realicen encuestas del estado de la instalaci\u00f3n, de manera que se pueda comprobar si las instalaciones conforme al RD 865\/2033 han sido adecuadas; es muy probable que la mayor parte de los casos registrados lo hayan sido en instalaciones m\u00e1s antiguas y, muy probablemente, mal mantenidas.<\/p>\n\n\n\n<p>La estad\u00edstica asociada al tipo de instalaciones aportar\u00eda datos muy valiosos para el dise\u00f1o de futuras instalaciones.<\/p>\n\n\n\n<p>Otro aspecto que debe aclararse es el alcance de las reformas a realizar, es decir si se deben cumplir todos los requisitos como las recirculaciones en puntos m\u00e1s alejados de 5 m, o si deben modificarse todas las instalaciones que no puedan vaciarse totalmente, o si son obligatorios dos dep\u00f3sitos en las instalaciones que actualmente tienen solo uno, si deben cambiarse los dep\u00f3sitos que no tienen los registros actualmente exigidos, etc.<\/p>\n\n\n\n<p>Puede quedar supeditado a un correcto PPCL y seguimiento de los an\u00e1lisis de muestras, actuando obligatoriamente cuando se registren datos con riesgo.<\/p>\n\n\n\n<p>Respecto al registro de los dep\u00f3sitos ser\u00eda suficiente con remitirlos a la norma UNE EN 12897, que admite otras soluciones, no \u00fanicamente la de 400 mm, adaptadas a las dimensiones de los dep\u00f3sitos; se podr\u00eda aplicar la exigencia de 400 mm para dep\u00f3sitos de m\u00e1s de 2.000 L que son el l\u00edmite de la UNE EN.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ricardo Garc\u00eda San Jos\u00e9 Vicepresidente del Comit\u00e9 T\u00e9cnico de Atecyr INTRODUCCI\u00d3N La prevenci\u00f3n de la legionelosis en instalaciones de Agua Caliente Sanitaria (ACS) es un tema de vital importancia para la salud p\u00fablica que&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":2534,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[5],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2978"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=2978"}],"version-history":[{"count":1,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2978\/revisions"}],"predecessor-version":[{"id":2983,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2978\/revisions\/2983"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/2534"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=2978"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=2978"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=2978"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}