{"id":2963,"date":"2025-02-28T13:31:25","date_gmt":"2025-02-28T12:31:25","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=2963"},"modified":"2025-02-28T13:31:26","modified_gmt":"2025-02-28T12:31:26","slug":"legionella-ii-esquemas-con-produccion-centralizada-de-acs-por-ricardo-garcia-san-jose","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2025\/02\/28\/legionella-ii-esquemas-con-produccion-centralizada-de-acs-por-ricardo-garcia-san-jose\/","title":{"rendered":"LEGIONELLA II: Esquemas con producci\u00f3n centralizada de ACS por Ricardo Garc\u00eda San Jos\u00e9"},"content":{"rendered":"\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"923\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ.png\" alt=\"\" class=\"wp-image-1057 size-full\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ.png 925w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-150x150.png 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-300x300.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-768x766.png 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-500x500.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-800x798.png 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-160x160.png 160w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-320x320.png 320w\" sizes=\"(max-width: 925px) 100vw, 925px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"><strong>Ricardo Garc\u00eda San Jos\u00e9<\/strong><\/p>\n\n\n\n<p>Vicepresidente del Comit\u00e9 T\u00e9cnico de Atecyr<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>La prevenci\u00f3n de la legionelosis en instalaciones de Agua Caliente Sanitaria (ACS) es un tema de vital importancia para la salud p\u00fablica que debe compaginarse con la eficiencia energ\u00e9tica.<\/p>\n\n\n\n<p>El Real Decreto 487\/2022 y sus modificaciones mediante el RD 614\/2024, han incluido unos requisitos sanitarios para el dise\u00f1o, mantenimiento y operaci\u00f3n de estas instalaciones que imponen unas variaciones importantes respecto a los utilizados con la aplicaci\u00f3n del RD 865\/2003.<\/p>\n\n\n\n<p>Este post es la continuaci\u00f3n del an\u00e1lisis iniciado en el primero de esta serie, en el que se explor\u00f3 l<strong><a href=\"https:\/\/www.atecyr.org\/blog\/2025\/02\/13\/evolucion-de-los-requisitos-reglamentarios-para-prevencion-de-la-legionelosis-en-instalaciones-de-acs-por-ricardo-garcia-san-jose\/\">a evoluci\u00f3n de los requisitos reglamentarios para la prevenci\u00f3n de la Legionelosis en instalaciones de ACS.<\/a><\/strong><\/p>\n\n\n\n<p><strong>2.3.- Producci\u00f3n con Interacumuladores<\/strong><\/p>\n\n\n\n<p>Los interacumuladores son dep\u00f3sitos para la producci\u00f3n de ACS que incorporan en su interior el intercambiador, tanto el dep\u00f3sito como el serpent\u00edn de calentamiento deben ser de material adecuado para estar en contacto con el agua de consumo humano.<\/p>\n\n\n\n<p>Con un \u00fanico dep\u00f3sito no es posible asegurar que la temperatura del agua en el interior del mismo tenga una temperatura homog\u00e9nea, en su parte inferior estar\u00e1 en muchos momentos con bajas temperaturas, ya que reciben continuamente el agua fr\u00eda que posteriormente se va a consumir, una vez calentada.<\/p>\n\n\n\n<p>Con m\u00e1s de un dep\u00f3sito, para un \u00f3ptimo aprovechamiento de la potencia de intercambio la conexi\u00f3n hidr\u00e1ulica m\u00e1s adecuada es en paralelo, pero con la misma en todos los dep\u00f3sitos se tienen zonas de mezcla que impiden la homogeneizaci\u00f3n de las temperaturas del agua acumulada, estando una parte a menor temperatura por la entrada continua del agua de consumo (Figura 5).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"509\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-1024x509.jpg\" alt=\"\" class=\"wp-image-2964\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-1024x509.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-300x149.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-768x382.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-1536x764.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-2048x1019.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-500x249.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-800x398.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-1280x637.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-5-1920x955.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 5<\/strong>: Esquemas de producci\u00f3n de ACS con interacumuladores, con un \u00fanico dep\u00f3sito o con dos dep\u00f3sitos hidr\u00e1ulicamente en paralelo.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"907\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-1024x907.jpg\" alt=\"\" class=\"wp-image-2965\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-1024x907.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-300x266.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-768x680.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-1536x1361.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-500x443.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-800x709.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-1280x1134.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6-1920x1701.jpg 1920w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-6.jpg 1999w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 6<\/strong>: Esquemas de producci\u00f3n de ACS con dos interacumuladores hidr\u00e1ulicamente en serie.<\/p>\n\n\n\n<p>Para asegurar en el dep\u00f3sito final la homogeneidad de la temperatura y el m\u00ednimo de 60\u00baC, los dep\u00f3sitos deben conectarse en serie (Figura 6), en cuyo caso el intercambiador del dep\u00f3sito final no proporciona toda su potencia ya que el salto t\u00e9rmico disminuye en gran medida al estar el agua en el dep\u00f3sito a 60\u00baC; esta es una soluci\u00f3n que cumple las prescripciones del RD 487\/2022, con las modificaciones del RD 614\/2024, seg\u00fan el cual la recirculaci\u00f3n puede volver a la distribuci\u00f3n.<\/p>\n\n\n\n<p>Para disponer de mayor potencia de intercambio pueden conectarse varios dep\u00f3sitos en paralelo y el conjunto pasar en serie por el dep\u00f3sito final (Figura 7), antes de salir a consumo, cumpliendo las prescripciones del RD; perdiendo solo la potencia del \u00faltimo intercambiador que se utiliza para asegurar la temperatura homog\u00e9nea y m\u00ednima de 60\u00baC.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"526\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-1024x526.jpg\" alt=\"\" class=\"wp-image-2966\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-1024x526.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-300x154.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-768x394.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-1536x788.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-2048x1051.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-500x257.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-800x411.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-1280x657.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-7-1920x986.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><a><strong>Figura 7<\/strong><\/a>: Esquemas de producci\u00f3n de ACS con cuatro interacumuladores los tres primeros hidr\u00e1ulicamente en paralelo conectados en serie con el dep\u00f3sito final.<\/p>\n\n\n\n<p><strong>2.4.- Producci\u00f3n con acumuladores de Doble Tanque<\/strong><\/p>\n\n\n\n<p>Funcionalmente se trata de interacumuladores, por lo que son aplicables los mismos criterios definidos en el apartado anterior (2.3), con la diferencia de que tienen sus tomas por la parte superior y disponen de menos conexiones. La temperatura de acumulaci\u00f3n debe ser de 70\u00baC, por lo que es absolutamente necesaria la regulaci\u00f3n antes de la distribuci\u00f3n del ACS (Figura 8).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"864\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-1024x864.jpg\" alt=\"\" class=\"wp-image-2967\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-1024x864.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-300x253.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-768x648.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-1536x1297.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-2048x1729.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-500x422.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-800x675.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-1280x1080.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-8-1920x1621.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 8<\/strong>: Esquemas de producci\u00f3n de ACS con dos interacumuladores de doble tanque conectados hidr\u00e1ulicamente en paralelo.<\/p>\n\n\n\n<p>Si se conectan hidr\u00e1ulicamente en paralelo, como corresponde a este tipo de equipos, esta temperatura no se alcanzar\u00e1 en toda el agua acumulada; para ello se deben conectar en serie o un grupo en paralelo con el \u00faltimo dep\u00f3sito en serie (Figura 9).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-1024x559.jpg\" alt=\"\" class=\"wp-image-2968\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-1024x559.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-300x164.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-768x419.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-1536x838.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-2048x1117.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-500x273.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-800x436.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-1280x698.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-9-1920x1048.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><a><strong>Figura 9<\/strong><\/a>: Esquemas de producci\u00f3n de ACS con tres interacumuladores de doble tanque conectados hidr\u00e1ulicamente en paralelo conectados en serie con un cuarto interacumulador.<\/p>\n\n\n\n<p><strong>2.5.- Producci\u00f3n con Dep\u00f3sitos e Intercambiadores de Placas<\/strong><\/p>\n\n\n\n<p>Al igual que con los interacumuladores, para asegurar la temperatura en los dep\u00f3sitos finales se requieren como m\u00ednimo dos dep\u00f3sitos; si bien con intercambiadores de placas la conexi\u00f3n que permite un \u00f3ptimo aprovechamiento de la potencia de intercambio es con los dep\u00f3sitos en serie, por lo que esta soluci\u00f3n se adecua al RD (Figura 10)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"658\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-1024x658.jpg\" alt=\"\" class=\"wp-image-2969\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-1024x658.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-300x193.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-768x494.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-1536x987.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-2048x1317.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-500x321.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-800x514.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-1280x823.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-10-1920x1234.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 10<\/strong>: Esquemas de producci\u00f3n de ACS con dos dep\u00f3sitos conectados hidr\u00e1ulicamente en serie e intercambiador exterior de placas<\/p>\n\n\n\n<p>Si la interpretaci\u00f3n de que la temperatura de los dep\u00f3sitos finales deba ser siempre como m\u00ednimo de 60\u00baC en toda el agua acumulada, la instalaci\u00f3n se debe dimensionar de manera que se haga frente a los momentos punta sin que se consuma toda el agua de los dep\u00f3sitos previos, ya que si se presenta esta circunstancia llegar\u00eda agua a temperatura inferior a 60\u00baC, esta situaci\u00f3n ser\u00eda de corta duraci\u00f3n, momentos punta, recuper\u00e1ndose la temperatura en breve tiempo una vez superada la punta (Figura 11).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"658\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-1024x658.jpg\" alt=\"\" class=\"wp-image-2970\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-1024x658.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-300x193.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-768x494.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-1536x987.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-2048x1317.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-500x321.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-800x514.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-1280x823.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-11-1920x1234.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 11<\/strong>: Esquemas de producci\u00f3n de ACS con dos dep\u00f3sitos conectados hidr\u00e1ulicamente en serie e intercambiador exterior de placas.<\/p>\n\n\n\n<p>Para garantizar que la temperatura siempre sea como m\u00ednimo de 60\u00baC, las soluciones m\u00e1s adecuadas son con tres, o m\u00e1s, dep\u00f3sitos en serie (Figura 12) dimensionando la instalaci\u00f3n de manera que los consumos en punta se cubran con los dep\u00f3sitos previos al dep\u00f3sito final.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"638\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-1024x638.jpg\" alt=\"\" class=\"wp-image-2971\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-1024x638.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-300x187.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-768x478.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-1536x956.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-2048x1275.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-500x311.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-800x498.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-1280x797.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-12-1920x1196.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 12<\/strong>: Esquemas de producci\u00f3n de ACS con tres dep\u00f3sitos conectados hidr\u00e1ulicamente en serie e intercambiador exterior de placas.<\/p>\n\n\n\n<p><strong>2.6.- Producci\u00f3n con Dep\u00f3sitos y dos Intercambiadores de placas de ACS<\/strong><\/p>\n\n\n\n<p>La colocaci\u00f3n de un segundo intercambiador de placas entre la entrada de agua fr\u00eda y la salida del ACS a consumo, consigue que toda el agua caliente incluso la de recirculaci\u00f3n pase por la alta temperatura antes de ir a consumo.<\/p>\n\n\n\n<p>En este segundo intercambiador se reduce la temperatura de distribuci\u00f3n precalentando al agua fr\u00eda para la producci\u00f3n de ACS, de manera que no se requiere un consumo de energ\u00eda adicional (Figura 13).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"376\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-1024x376.jpg\" alt=\"\" class=\"wp-image-2972\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-1024x376.jpg 1024w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-300x110.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-768x282.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-1536x564.jpg 1536w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-2048x752.jpg 2048w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-500x184.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-800x294.jpg 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-1280x470.jpg 1280w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Figura-13-1920x705.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Figura 13<\/strong>: Esquemas de producci\u00f3n de ACS con dos intercambiadores de placas, uno en la entrada de agua fr\u00eda y recirculaci\u00f3n y otro para el calentamiento del agua acumulada; soluciones con uno y dos dep\u00f3sitos.<\/p>\n\n\n\n<p>Con un \u00fanico dep\u00f3sito en los momentos punta en la parte inferior del mismo pueden tenerse temperaturas menores, por lo que para asegurar en todo momento que esa temperatura es al menos de 60\u00baC son necesarios, al menos, dos dep\u00f3sitos.<\/p>\n\n\n\n<p>Hay previsto publicar un tercer y \u00faltimo post en el que se abordar\u00e1, en profundidad:<\/p>\n\n\n\n<ul>\n<li>La regulaci\u00f3n de la temperatura de distribuci\u00f3n.<\/li>\n\n\n\n<li>Las distribuciones interiores.<\/li>\n\n\n\n<li>La adecuaci\u00f3n de instalaciones existentes.<\/li>\n\n\n\n<li>El Plan de Prevenci\u00f3n y Control de Legionella.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Ricardo Garc\u00eda San Jos\u00e9 Vicepresidente del Comit\u00e9 T\u00e9cnico de Atecyr La prevenci\u00f3n de la legionelosis en instalaciones de Agua Caliente Sanitaria (ACS) es un tema de vital importancia para la salud p\u00fablica que debe&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":2534,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[5],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2963"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=2963"}],"version-history":[{"count":1,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2963\/revisions"}],"predecessor-version":[{"id":2973,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2963\/revisions\/2973"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/2534"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=2963"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=2963"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=2963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}