{"id":2933,"date":"2025-02-13T11:23:51","date_gmt":"2025-02-13T10:23:51","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=2933"},"modified":"2025-02-17T15:13:32","modified_gmt":"2025-02-17T14:13:32","slug":"evolucion-de-los-requisitos-reglamentarios-para-prevencion-de-la-legionelosis-en-instalaciones-de-acs-por-ricardo-garcia-san-jose","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2025\/02\/13\/evolucion-de-los-requisitos-reglamentarios-para-prevencion-de-la-legionelosis-en-instalaciones-de-acs-por-ricardo-garcia-san-jose\/","title":{"rendered":"LEGIONELLA I: Evoluci\u00f3n de los requisitos reglamentarios para prevenci\u00f3n de la legionelosis en instalaciones de ACS por Ricardo Garc\u00eda San Jos\u00e9"},"content":{"rendered":"\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"923\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ.png\" alt=\"\" class=\"wp-image-1057 size-full\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ.png 925w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-150x150.png 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-300x300.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-768x766.png 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-500x500.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-800x798.png 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-160x160.png 160w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2019\/11\/Ricardo-GSJ-320x320.png 320w\" sizes=\"(max-width: 925px) 100vw, 925px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"><strong>Ricardo Garc\u00eda San Jos\u00e9<\/strong><\/p>\n\n\n\n<p>Vicepresidente del Comit\u00e9 T\u00e9cnico de Atecyr<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>La prevenci\u00f3n de la legionelosis en instalaciones de Agua Caliente Sanitaria (ACS) es un tema de vital importancia para la salud p\u00fablica que debe compaginarse con la eficiencia energ\u00e9tica.<\/p>\n\n\n\n<p>El Real Decreto 487\/2022 y sus modificaciones mediante el RD 614\/2024, han incluido unos requisitos sanitarios para el dise\u00f1o, mantenimiento y operaci\u00f3n de estas instalaciones que imponen unas variaciones importantes respecto a los utilizados con la aplicaci\u00f3n del RD 865\/2003.<\/p>\n\n\n\n<p>En nuevas instalaciones el cumplimiento de estas exigencias no presenta problemas t\u00e9cnicos, aunque en algunos aspectos pueden requerir inversiones m\u00e1s altas, pero en las instalaciones existentes se tienen mayores dificultades, sobre todo las que se pueden derivar de la obligatoriedad de adaptaci\u00f3n a los nuevos requisitos, en la disposici\u00f3n transitoria cuarta del RD 487\/2022 se estableci\u00f3 un plazo para su adecuaci\u00f3n, que ha finalizado el pasado 2 de enero.<\/p>\n\n\n\n<p>Esta adecuaci\u00f3n supone que en muchos edificios se deban reformar de manera importante las instalaciones existentes.<\/p>\n\n\n\n<p>Este art\u00edculo explora los cambios normativos, su impacto en las instalaciones existentes y las mejores pr\u00e1cticas para garantizar la seguridad sanitaria, optimizando al mismo tiempo el rendimiento de los sistemas; teniendo en cuenta que el RD no se aplica a las instalaciones en los edificios de viviendas el alcance del art\u00edculo se concentra en las instalaciones de producci\u00f3n de ACS centrales.<\/p>\n\n\n\n<p>Este es el primer post de una serie de tres, en los que se ha dividido el art\u00edculo, y en los que se analizar\u00e1 en profundidad los Reales Decretos antes mencionados y su impacto en la adecuaci\u00f3n de las instalaciones t\u00e9rmicas de ACS.<\/p>\n\n\n\n<p><strong>1.- EVOLUCI\u00d3N DE LOS REQUISITOS REGLAMENTARIOS PARA PREVENCI\u00d3N DE LA LEGIONELOSIS EN INSTALACIONES DE ACS<\/strong><\/p>\n\n\n\n<p><strong>1.1.- Requisitos del RD 865\/2003<\/strong><\/p>\n\n\n\n<p>Para analizar correctamente el alcance de las reformas necesarias en las instalaciones existentes, es necesario en primer lugar describir los requisitos del RD 865\/2003, los m\u00e1s significativos son:<\/p>\n\n\n\n<ul>\n<li>Garantizar la total estanqueidad y la correcta circulaci\u00f3n del agua, evitando su estancamiento, as\u00ed como disponer de suficientes puntos de purga para <strong>vaciar completamente la instalaci\u00f3n<\/strong>, que estar\u00e1n dimensionados para permitir la eliminaci\u00f3n completa de los sedimentos<\/li>\n\n\n\n<li>Disponer en el agua de aporte sistemas de <strong>filtraci\u00f3n<\/strong>. (Este requisito fue posteriormente incluido en el HS4 del CTE 2006).<\/li>\n\n\n\n<li>Facilitar la <strong>accesibilidad<\/strong> a los equipos para su inspecci\u00f3n, limpieza, desinfecci\u00f3n y toma de muestras.<\/li>\n\n\n\n<li>Utilizar <strong>materiales<\/strong>, en contacto con el agua de consumo humano, capaces de <strong>resistir una desinfecci\u00f3n <\/strong>mediante elevadas concentraciones de cloro o de otros desinfectantes <strong>o por elevaci\u00f3n de temperatura<\/strong>, evitando aquellos que favorezcan el crecimiento microbiano y la formaci\u00f3n de biocapa en el interior de las tuber\u00edas.<\/li>\n\n\n\n<li>Mantener la temperatura del agua en el circuito de <strong>agua fr\u00eda<\/strong> lo m\u00e1s baja posible procurando, donde las condiciones climatol\u00f3gicas lo permitan, una temperatura inferior a <strong>20\u00baC<\/strong>, para lo cual las tuber\u00edas estar\u00e1n suficientemente <strong>alejadas<\/strong> de las de agua caliente <strong>o<\/strong> en su defecto <strong>aisladas t\u00e9rmicamente<\/strong>.<\/li>\n\n\n\n<li>Asegurar, en <strong>toda el agua almacenada<\/strong> en los <strong>acumuladores<\/strong> de agua caliente <strong>finales<\/strong>, es decir, inmediatamente anteriores a consumo, una <strong>temperatura homog\u00e9nea<\/strong> y evitar el enfriamiento de zonas interiores que propicien la formaci\u00f3n y proliferaci\u00f3n de la flora bacteriana.<\/li>\n\n\n\n<li>Disponer de un sistema de <strong>v\u00e1lvulas de retenci\u00f3n<\/strong>, seg\u00fan la norma UNE-EN 1717. (El documento HS4 indica los puntos m\u00ednimos donde las mismas deben instalarse)<\/li>\n\n\n\n<li>Mantener la temperatura del agua, en el <strong>circuito de agua caliente, por encima de 50\u00baC<\/strong> en el punto m\u00e1s alejado del circuito o en la tuber\u00eda de retorno al acumulador (En el HS4 se estableci\u00f3 una distancia m\u00e1xima de tuber\u00eda sin recirculaci\u00f3n de 15 m). La instalaci\u00f3n permitir\u00e1 que el agua <strong>alcance una temperatura de 70\u00baC<\/strong>.<\/li>\n\n\n\n<li>Cuando se utilice un sistema de <strong>aprovechamiento t\u00e9rmico<\/strong> en el que se disponga de un acumulador conteniendo agua que va a ser consumida y en el que no se asegure de forma continua una temperatura pr\u00f3xima a 60\u00baC, se garantizar\u00e1 posteriormente, que se alcance una temperatura de <strong>60\u00baC en otro acumulador final<\/strong> antes de la distribuci\u00f3n hacia el consumo<\/li>\n<\/ul>\n\n\n\n<p>B\u00e1sicamente estos requisitos son similares a los actuales del RD 487\/2022, por lo que las instalaciones que ya cumpl\u00edan el RD 865\/2003 no debieran tener impedimentos importantes para adecuarse.<\/p>\n\n\n\n<p>Las mayores dificultades se pueden tener en las instalaciones anteriores a 2003, ya que en la disposici\u00f3n transitoria \u00fanica del RD 865\/2003 \u201cAdecuaci\u00f3n de las instalaciones\u201d, se indic\u00f3:<\/p>\n\n\n\n<p><em>Las instalaciones interiores de agua de consumo humano existentes a la entrada en vigor de esta disposici\u00f3n dispondr\u00e1n de un a\u00f1o para adoptar las medidas establecidas en el art\u00edculo 7.1, p\u00e1rrafo f).<\/em><\/p>\n\n\n\n<p>Que solo afectaba a los dep\u00f3sitos de agua fr\u00eda:<\/p>\n\n\n\n<p><em>f) Garantizar que, si la instalaci\u00f3n interior de agua fr\u00eda de consumo humano dispone de dep\u00f3sitos, \u00e9stos est\u00e9n tapados con una cubierta impermeable que ajuste perfectamente y que permita el acceso al interior. Si se encuentran situados al aire libre estar\u00e1n t\u00e9rmicamente aislados. Si se utiliza cloro como desinfectante, se a\u00f1a dir\u00e1, si es necesario, al dep\u00f3sito mediante dosificadores autom\u00e1ticos.<\/em><\/p>\n\n\n\n<p>Una reflexi\u00f3n en este sentido es que el RD 909\/2001 en su Disposici\u00f3n Transitoria segunda. \u201c<em>Adecuaci\u00f3n de las instalaciones<\/em>\u201d, hab\u00eda establecido un plazo de solo seis meses para su adecuaci\u00f3n completa, generando un agravio comparativo entre las instalaciones que ya se hubiesen adecuado en 2002 y las que no lo hubieran hecho que quedaron exentas en 2003.<\/p>\n\n\n\n<p><em>Los titulares de las instalaciones existentes a la entrada en vigor del presente Real Decreto (909\/2001) adecuar\u00e1n sus instalaciones en un plazo de seis meses, a contar desde su entrada en vigor. En caso de que dicha adecuaci\u00f3n de las instalaciones no pudiera efectuarse en el plazo anteriormente se\u00f1alado, \u00e9ste podr\u00e1 ser ampliado, previa solicitud razonada del interesado, por la autoridad sanitaria competente, que deber\u00e1 notificar la resoluci\u00f3n correspondiente en el transcurso de los veinte d\u00edas h\u00e1biles siguientes a la solicitud.<\/em><\/p>\n\n\n\n<p><strong>1.2.- Requisitos diferenciales incluidos en el RD 487\/2022 y sus modificaciones RD 614\/2024<\/strong><\/p>\n\n\n\n<p>Para las instalaciones de ACS, respecto al RD 865\/2003 se han incorporado las siguientes exigencias:<\/p>\n\n\n\n<ul>\n<li><strong>Boca de registro<\/strong>: Los elementos de acumulaci\u00f3n de agua de 750 litros o m\u00e1s deber\u00e1n disponer de boca de registro f\u00e1cilmente accesible, con un di\u00e1metro m\u00ednimo de 400 mm, que permita realizar operaciones de inspecci\u00f3n, limpieza, desinfecci\u00f3n, mantenimiento y protecci\u00f3n contra la corrosi\u00f3n. Los dep\u00f3sitos de acumulaci\u00f3n entre 250 y 750 litros y los interacumuladores de doble tanque (con vol\u00famenes de acumulaci\u00f3n de agua inferiores a 750 litros) estar\u00e1n provistos de los correspondientes accesos para inspecci\u00f3n, limpieza, vaciado y toma de muestras adecuados a sus caracter\u00edsticas de dise\u00f1o definidas en la Norma <strong>UNE EN 12897:2017+A1:2020<\/strong> Especificaciones para calentadores de agua de acumulaci\u00f3n por calentamiento indirecto sin ventilaci\u00f3n (cerrados).<\/li>\n\n\n\n<li><strong>Temperatura en los acumuladores<\/strong>: Asegurar\u00e1, en <strong>toda el agua<\/strong> almacenada en los acumuladores de agua caliente finales, es decir, inmediatamente anteriores a consumo, una temperatura <strong>homog\u00e9nea y m\u00ednima de 60\u00baC<\/strong>. En el caso de <strong>interacumuladores de doble tanque<\/strong>, la temperatura del agua debe ser como m\u00ednimo de <strong>70\u00b0C<\/strong>.<\/li>\n\n\n\n<li>Los acumuladores estar\u00e1n dotados de un sistema de medida de temperatura representativo del agua interior y dotados de llave de purga accesible en la zona m\u00e1s baja del dep\u00f3sito que permita el vaciado completo y la toma de muestras y que adem\u00e1s se situar\u00e1 con nivel inferior a la salida del agua.<\/li>\n\n\n\n<li><strong>Sistemas sin acumulaci\u00f3n<\/strong>: Los sistemas de calentamiento sin acumulaci\u00f3n con y sin retorno, garantizar\u00e1n que el agua a la salida del sistema de calentamiento tenga una temperatura <strong>m\u00ednima de 60\u00baC<\/strong>.<\/li>\n\n\n\n<li>Los tramos de tuber\u00edas en los que no se pueda asegurar una circulaci\u00f3n del agua y una temperatura m\u00ednima superior a 50\u00baC no podr\u00e1n tener una longitud superior a <strong>5 metros<\/strong> <strong>o<\/strong> un volumen de agua almacenada superior a <strong>3 litros<\/strong>. Esto ser\u00e1 aplicable a los sistemas de v\u00e1lvula mezcladora, en los que se deben garantizar 50\u00baC antes de la propia v\u00e1lvula y disponer de un sistema de medici\u00f3n de la temperatura. La temperatura de estabilizaci\u00f3n deber\u00e1 alcanzarse antes de transcurrido un minuto.<\/li>\n\n\n\n<li>Para instalaciones de usuarios inmunocomprometidos, se recomienda la instalaci\u00f3n de filtros microbiol\u00f3gicos de probada eficacia frente a Legionella u otros sistemas de an\u00e1loga eficacia en los puntos terminales.<\/li>\n<\/ul>\n\n\n\n<p>Respecto a la boca de registro existe una discrepancia en la capacidad de 750 L ya que en un p\u00e1rrafo indica la exigencia de la boca de registro de 400 mm y en el siguiente ese volumen se remite a la norma <strong>UNE EN 12987<\/strong>; teniendo en cuenta que el objetivo de esta exigencia es poder asegurar la limpieza interior de los dep\u00f3sitos, hubiese sido suficiente con remitir todas las capacidades a las bocas de registro definidas en esa norma UNE EN, las cuales se muestran en las Tablas 1 y 2:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"948\" height=\"373\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/1.jpg\" alt=\"\" class=\"wp-image-2935\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/1.jpg 948w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/1-300x118.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/1-768x302.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/1-500x197.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/1-800x315.jpg 800w\" sizes=\"(max-width: 948px) 100vw, 948px\" \/><\/figure><\/div>\n\n\n<p><strong>Tabla 1<\/strong>: Caracter\u00edsticas de los registros de acceso para interacumuladores para ACS (UNE EN 12987 2017 + A1 2020.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"948\" height=\"312\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/2.jpg\" alt=\"\" class=\"wp-image-2936\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/2.jpg 948w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/2-300x99.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/2-768x253.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/2-500x165.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/2-800x263.jpg 800w\" sizes=\"(max-width: 948px) 100vw, 948px\" \/><\/figure><\/div>\n\n\n<p><strong>Tabla 2<\/strong>: Caracter\u00edsticas de los registros de acceso para dep\u00f3sitos de ACS (UNE EN 12987 2017 + A1 2020).<\/p>\n\n\n\n<p>Las aberturas especificadas en esta norma se refieren a los vol\u00famenes reales que pueden no coincidir exactamente con los nominales de cat\u00e1logo, atendiendo a las tolerancias definidas en la misma norma (Tabla 3)<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"498\" height=\"101\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/3.jpg\" alt=\"\" class=\"wp-image-2937\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/3.jpg 498w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/3-300x61.jpg 300w\" sizes=\"(max-width: 498px) 100vw, 498px\" \/><\/figure><\/div>\n\n\n<p><strong>Tabla 3<\/strong>: Tolerancias para las capacidades de los dep\u00f3sitos para ACS hasta 2.000 L (UNE EN 12987 2017 + A1 2020).<\/p>\n\n\n\n<p>En este sentido en la Disposici\u00f3n adicional tercera, Requisitos de dep\u00f3sitos e interacumuladores de doble tanque con volumen inferior a 750 litros, se especifica:<\/p>\n\n\n\n<p><em>Los dep\u00f3sitos de acumulaci\u00f3n entre 250 y 750 litros y los interacumuladores de doble tanque con volumen de acumulaci\u00f3n de agua inferiores a 750 litros, de ACS, <strong>existentes<\/strong> con anterioridad a la entrada en vigor del presente real decreto, deber\u00e1n cumplir las caracter\u00edsticas de los accesos para inspecci\u00f3n, limpieza, vaciado y toma de muestras adecuados a las caracter\u00edsticas de dise\u00f1o definidas en la Norma UNE-EN 12897:2017+A1:2020 Especificaciones para calentadores de agua por acumulaci\u00f3n por calentamiento indirecto sin ventilaci\u00f3n (cerrados), tras la sustituci\u00f3n de los mismos.<\/em><\/p>\n\n\n\n<p>En la temperatura de los dep\u00f3sitos a la exigencia de <strong>homog\u00e9nea<\/strong> se le ha a\u00f1adido la de <strong>m\u00ednima<\/strong> <strong>de 60\u00baC<\/strong>, lo que se ha interpretado como que en todo momento se deben mantener los 60\u00baC en todos los dep\u00f3sitos finales, siendo uno de los aspectos m\u00e1s conflictivos de interpretaci\u00f3n.<\/p>\n\n\n\n<p>La prescripci\u00f3n de toda el agua a temperatura homog\u00e9nea ya se ten\u00eda en el RD 865\/2003, pero como en aquel los 60\u00baC se mencionaban en un p\u00e1rrafo posterior, asociado a energ\u00edas renovables o recuperaci\u00f3n de calor, las instalaciones se han dise\u00f1ado de manera que el agua, antes de salir a consumo, siempre ha estado a 60\u00baC pero permitiendo enfriamientos temporales de la parte inferior del dep\u00f3sito al menos en las puntas de consumo, o de manera permanente cuando la instalaci\u00f3n dispon\u00eda de un \u00fanico dep\u00f3sito.<\/p>\n\n\n\n<p>En interacumuladores de doble tanque la exigencia de temperatura se eleva hasta los 70\u00baC, posiblemente debido a la dificultad, de homogeneidad de la temperatura; situaci\u00f3n que tambi\u00e9n se da en los interacumuladores, en los que no se ha incrementado la exigencia.<\/p>\n\n\n\n<p>Un cambio muy notable es la exigencia de 60\u00baC tambi\u00e9n para producci\u00f3n instant\u00e1nea con y sin recirculaci\u00f3n, que tradicionalmente se ha limitado a algunos grados por encima de 50\u00baC, asegurando esta temperatura es los puntos m\u00e1s alejados cuando hay recirculaci\u00f3n.<\/p>\n\n\n\n<p>El nuevo requisito de distancia m\u00e1xima sin recirculaci\u00f3n a 5 m o a 3 L, siempre la que resulte menor, reduce de manera importante los 15 m de referencia del HS4; lo que puede obligar a llevar la recirculaci\u00f3n hasta el interior de los cuartos h\u00famedos e incluso hasta los aparatos (Figura 1).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"974\" height=\"385\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/4.jpg\" alt=\"\" class=\"wp-image-2938\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/4.jpg 974w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/4-300x119.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/4-768x304.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/4-500x198.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/4-800x316.jpg 800w\" sizes=\"(max-width: 974px) 100vw, 974px\" \/><\/figure><\/div>\n\n\n<p><strong>Figura 1<\/strong>: Esquema de distribuciones generales de ACS con indicaci\u00f3n de las intervenciones en el interior de los cuarto h\u00famedos.<\/p>\n\n\n\n<p>La modificaci\u00f3n del RD 614\/2024 ha eliminado la prohibici\u00f3n de que la recirculaci\u00f3n pudiese volver a consumo sin pasar por el calentamiento a 60\u00baC; por ello puede aplicarse las soluciones habituales con v\u00e1lvulas motorizadas de tres v\u00edas conectando la recirculaci\u00f3n a los dep\u00f3sitos y a la v\u00eda de agua fr\u00eda, o v\u00e1lvulas termost\u00e1ticas de cuatro v\u00edas con conexi\u00f3n directa de la recirculaci\u00f3n.<\/p>\n\n\n\n<p><strong>2..- ESQUEMAS CON PRODUCCI\u00d3N CENTRALIZADA DE ACS AJUSTADOS AL RD 487\/2022 CON LAS MODIFICACIONES DEL RD 614\/2024<\/strong><\/p>\n\n\n\n<p>En este apartado se analizan las formas de producci\u00f3n de ACS, desde el punto de vista de los secundarios que es donde se tiene el riesgo de desarrollo de la Legionella.<\/p>\n\n\n\n<p>Se supone que los generadores t\u00e9rmicos proporcionan las temperaturas de primario suficientes; no se detallan los esquemas de integraci\u00f3n de calderas o bombas de calor de alta o media temperatura.<\/p>\n\n\n\n<p><strong>2.1.- Producci\u00f3n Instant\u00e1nea<\/strong><\/p>\n\n\n\n<p>La producci\u00f3n debe alcanzar los 60\u00baC, puede distribuirse directamente a esa temperatura cumpliendo en el punto m\u00e1s alejado en nivel de 50\u00baC; si se necesita mantener m\u00e1s estable la temperatura de distribuci\u00f3n puede complementarse con una regulaci\u00f3n de la temperatura en secundario, distribuyendo a unos 53\u00baC (Figura 2).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"816\" height=\"443\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo1.jpg\" alt=\"\" class=\"wp-image-2956\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo1.jpg 816w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo1-300x163.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo1-768x417.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo1-500x271.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo1-800x434.jpg 800w\" sizes=\"(max-width: 816px) 100vw, 816px\" \/><\/figure><\/div>\n\n\n<p><strong>Figura 2<\/strong>: Esquemas de producci\u00f3n instant\u00e1nea de ACS directamente a 60\u00baC o con una regulaci\u00f3n posterior.<\/p>\n\n\n\n<p>La ausencia de recirculaci\u00f3n solo ser\u00eda admisible para distancias inferiores a 5 m y contenidos de agua m\u00e1ximos de 3 L.<\/p>\n\n\n\n<p><strong>2.2.- Producci\u00f3n Instant\u00e1nea con acumulaci\u00f3n en primario<\/strong><\/p>\n\n\n\n<p>La producci\u00f3n instant\u00e1nea tiene menos riesgo de desarrollo de la Legionella, como contrapartida requiere potencias de producci\u00f3n habitualmente muy altas, para reducirlas se tienen soluciones que acumulan la energ\u00eda en primario y producen el ACS de manera instant\u00e1nea; pueden ser con dep\u00f3sitos e intercambiadores de placas o con dep\u00f3sitos con intercambiador de calentamiento interno (Figuras 3 y 4).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"920\" height=\"443\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo2.jpg\" alt=\"\" class=\"wp-image-2957\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo2.jpg 920w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo2-300x144.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo2-768x370.jpg 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo2-500x241.jpg 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo2-800x385.jpg 800w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/figure><\/div>\n\n\n<p><strong>Figura 3<\/strong>: Esquemas de producci\u00f3n instant\u00e1nea de ACS con acumulaci\u00f3n en primario con intercambiador de placas, directamente a 60\u00baC o con una regulaci\u00f3n posterior.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"562\" height=\"443\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo3.jpg\" alt=\"\" class=\"wp-image-2958\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo3.jpg 562w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo3-300x236.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2025\/02\/Ricardo3-500x394.jpg 500w\" sizes=\"(max-width: 562px) 100vw, 562px\" \/><\/figure><\/div>\n\n\n<p><strong>Figura 4<\/strong>: Esquemas de producci\u00f3n instant\u00e1nea de ACS con acumulaci\u00f3n en primario, con calentamiento por serpent\u00edn interior en el dep\u00f3sito.<\/p>\n\n\n\n<p>El dep\u00f3sito no necesita ser de calidad sanitaria ya que el agua que acumula es la del sistema de generaci\u00f3n, el intercambiador debe tener la potencia de producci\u00f3n instant\u00e1nea; la regulaci\u00f3n de la temperatura de distribuci\u00f3n puede ser directamente a 60\u00baC o disponer la v\u00e1lvula en secundario para reducir de 60\u00baC a 53\u00baC, asegurando siempre un retorno a 50\u00baC.<\/p>\n\n\n\n<p>En el pr\u00f3ximo post, se abordar\u00e1 el resto de tipolog\u00edas de producci\u00f3n:<\/p>\n\n\n\n<ul>\n<li>La producci\u00f3n con Interacumuladores.<\/li>\n\n\n\n<li>La producci\u00f3n con acumuladores de Doble Tanque.<\/li>\n\n\n\n<li>La producci\u00f3n con Dep\u00f3sitos e Intercambiadores de Placas.<\/li>\n\n\n\n<li>La producci\u00f3n con Dep\u00f3sitos y dos Intercambiadores de placas de ACS.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Ricardo Garc\u00eda San Jos\u00e9 Vicepresidente del Comit\u00e9 T\u00e9cnico de Atecyr La prevenci\u00f3n de la legionelosis en instalaciones de Agua Caliente Sanitaria (ACS) es un tema de vital importancia para la salud p\u00fablica que debe&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":2534,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[5],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2933"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=2933"}],"version-history":[{"count":4,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2933\/revisions"}],"predecessor-version":[{"id":2961,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/2933\/revisions\/2961"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/2534"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=2933"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=2933"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=2933"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}