{"id":1844,"date":"2020-11-17T17:32:40","date_gmt":"2020-11-17T16:32:40","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=1844"},"modified":"2020-11-17T17:32:40","modified_gmt":"2020-11-17T16:32:40","slug":"difusion-de-aire-por-antonio-vegas-casado","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2020\/11\/17\/difusion-de-aire-por-antonio-vegas-casado\/","title":{"rendered":"Difusi\u00f3n de aire por Antonio Vegas Casado"},"content":{"rendered":"\n<div class=\"wp-block-media-text alignwide\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"397\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vegas.jpg.png\" alt=\"\" class=\"wp-image-1850\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vegas.jpg.png 401w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vegas.jpg-300x297.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vegas.jpg-150x150.png 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"><strong>Antonio Vegas Casado<\/strong><\/p>\n\n\n\n<p>Miembro honor\u00edfico del Comit\u00e9 T\u00e9cnico de Atecyr<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>Aunque todos los componentes que integran una instalaci\u00f3n de climatizaci\u00f3n son importantes, la difusi\u00f3n de aire tiene un papel fundamental. Con el aire que impulsamos en cada local aportamos la cantidad de energ\u00eda para compensar su carga sensible, y a la vez permite mantener en la zona de ocupaci\u00f3n la velocidad del aire y los valores de temperatura y humedad dentro de los l\u00edmites de confort. As\u00ed mismo, con el caudal de aire impulsado &nbsp;aportamos los niveles de ventilaci\u00f3n fijados en la normativa vigente, permitiendo la renovaci\u00f3n del aire en los locales y con ello evitar el incremento de la carga v\u00edrica que pueda afectar a los propios usuarios.<\/p>\n\n\n\n<p>Atecyr, patrocinado por TROX TECHNIK, ha editado el Documento T\u00e9cnico de Instalaciones en la Edificaci\u00f3n DTIE 13.01, sobre difusi\u00f3n de aire. El documento tiene como finalidad dotar al t\u00e9cnico de una herramienta que pueda serle \u00fatil para adquirir unos conocimientos b\u00e1sicos sobre difusi\u00f3n de aire y sobre las caracter\u00edsticas de las unidades terminales a trav\u00e9s de las cuales se realiza la impulsi\u00f3n del aire. El documento permite ver conceptos fundamentales de la difusi\u00f3n del aire, diferentes modelos y tipos de unidades terminales a trav\u00e9s de las cuales &nbsp;realizamos la impulsi\u00f3n, sus caracter\u00edsticas, as\u00ed como ejemplos de selecci\u00f3n y aplicaci\u00f3n de casos reales de funcionamiento.<\/p>\n\n\n\n<p><strong>Movimiento del Aire<\/strong><\/p>\n\n\n\n<p>En todos los locales climatizados, con independencia del sistema de climatizaci\u00f3n que utilicemos, siempre necesitamos impulsar un caudal de aire con el que se aporte la energ\u00eda necesaria para compensar las ganancias o p\u00e9rdidas de calor sensible. El caudal de aire impulsado depender\u00e1 del sistema de climatizaci\u00f3n que utilicemos:<\/p>\n\n\n\n<ul><li>Todo aire: el 100% de la energ\u00eda se aporta impulsando aire.<\/li><li>Aire\/agua: aproximadamente se aporta un 75% de la energ\u00eda con agua y un 25% con aire.<\/li><\/ul>\n\n\n\n<p>En los sistemas todo aire, las unidades terminales de impulsi\u00f3n las podemos colocar en cualquier parte del local:<\/p>\n\n\n\n<ul><li>Suelo&nbsp;&nbsp;<\/li><li>Techo<\/li><li>Paredes<\/li><li>Antepecho de las ventanas&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/li><\/ul>\n\n\n\n<p>Antes de hacer la selecci\u00f3n del tama\u00f1o de la unidad terminal de impulsi\u00f3n es muy importante que tengamos unos minutos de reflexi\u00f3n para saber.<\/p>\n\n\n\n<ul><li>Como funciona .<\/li><li>Donde debemos instalarla.<\/li><li>Que valores l\u00edmite hemos de cumplir.<\/li><li>Si podremos cumplir esos valores l\u00edmite con la unidad terminal seleccionada.<\/li><\/ul>\n\n\n\n<p>Es importante no considerar a la unidad terminal de impulsi\u00f3n como un elemento m\u00e1s de la decoraci\u00f3n del local. La unidad terminal de impulsi\u00f3n, tiene misiones m\u00e1s importantes como:<\/p>\n\n\n\n<ul><li>Distribuir el aire uniformemente.<\/li><li>Evitar velocidades de aire y diferencias de temperatura elevadas en la zona de ocupaci\u00f3n.<\/li><\/ul>\n\n\n\n<p>En los sistemas todo aire, el caudal de aire impulsado siempre es mayor que el volumen del local, por lo que se han de tener en cuenta varios factores que influyen en el movimiento del aire que pueden causar molestias en las personas por incremento de la velocidad del aire en la zona de ocupaci\u00f3n.<\/p>\n\n\n\n<p>Los factores que influyen en el movimiento del aire son:<\/p>\n\n\n\n<ul><li>Geometr\u00eda de las propias unidades terminales de impulsi\u00f3n y su situaci\u00f3n.<\/li><li>Temperatura y velocidad del aire impulsado.<\/li><li>Situaci\u00f3n de las unidades de retorno del aire.<\/li><li>Geometr\u00eda del local y situaci\u00f3n del mobiliario.<\/li><li>Situaci\u00f3n de los cerramientos exteriores con relaci\u00f3n a las unidades terminales de impulsi\u00f3n.<\/li><li>Temperatura de los cerramientos del local.<\/li><\/ul>\n\n\n\n<p>Teniendo en cuenta que una de las causas m\u00e1s importantes que provocan la incomodidad de las personas son altas velocidades del aire y altos \u00edndices de turbulencia, junto con diferencias de temperatura entre pies y cabeza, es importante:<\/p>\n\n\n\n<ul><li>Controlar los movimientos del aire en el local y respetar las velocidades de aire m\u00e1ximas admisibles en la zona de ocupaci\u00f3n.<\/li><li>Tener en cuenta que las velocidades del aire en el local est\u00e1n afectadas por las caracter\u00edsticas del flujo de aire de la unidad terminal de impulsi\u00f3n y su situaci\u00f3n.<\/li><\/ul>\n\n\n\n<p><strong>M\u00e9todos de difusi\u00f3n de aire<\/strong><\/p>\n\n\n\n<p>La difusi\u00f3n de aire, podemos definirla \u201ccomo el hecho de introducir de forma controlada un caudal de aire en el local a climatizar\u201d.<\/p>\n\n\n\n<p>Habitualmente se realiza por:<\/p>\n\n\n\n<ul><li>Mezcla de aire<\/li><li>Desplazamiento<\/li><\/ul>\n\n\n\n<p>Cuando se quiere gran calidad del aire como en los quir\u00f3fanos tipo A de alta exigencia seg\u00fan UNE 100713, o salas blancas, se utiliza:<\/p>\n\n\n\n<ul><li>Flujo laminar<\/li><\/ul>\n\n\n\n<p>En cada caso y en funci\u00f3n del tipo de local, caudal de aire a impulsar, calidad del aire,&nbsp; condiciones del aire impulsado y condiciones a mantener en el interior de los locales se utilizar\u00e1 uno de los sistemas de difusi\u00f3n anteriores.<\/p>\n\n\n\n<p><strong>Difusi\u00f3n por mezcla de aire<\/strong> El sistema de difusi\u00f3n por mezcla de aire es el que habitualmente se utiliza en las instalaciones de climatizaci\u00f3n.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"634\" height=\"411\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_1-1.jpg\" alt=\"\" class=\"wp-image-1846\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_1-1.jpg 634w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_1-1-300x194.jpg 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_1-1-500x324.jpg 500w\" sizes=\"(max-width: 634px) 100vw, 634px\" \/><\/figure><\/div>\n\n\n\n<p>Con este sistema impulsamos un caudal de aire con velocidad y diferencia de temperatura elevada con respecto a la temperatura del local. Con ello pretendemos una r\u00e1pida mezcla del aire impulsado con el aire ambiente, con el fin de que se unifiquen las temperaturas y se reduzca la velocidad del aire en la zona de ocupaci\u00f3n r\u00e1pidamente.<\/p>\n\n\n\n<p>Resumiendo las caracter\u00edsticas de este sistema de difusi\u00f3n son:<\/p>\n\n\n\n<ul><li>Las unidades terminales de impulsi\u00f3n se pueden colocar en techo, paredes, suelo o antepecho de las ventanas.<\/li><li>Las velocidades de impulsi\u00f3n son altas.<\/li><li>La mezcla del aire impulsado se realiza por inducci\u00f3n con el aire ambiente.<\/li><li>Los perfiles de temperatura, velocidad y contaminaci\u00f3n son uniformes.<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"553\" height=\"256\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_2.png\" alt=\"\" class=\"wp-image-1847\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_2.png 553w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_2-300x139.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_2-500x231.png 500w\" sizes=\"(max-width: 553px) 100vw, 553px\" \/><\/figure><\/div>\n\n\n\n<ul><li>El retorno del aire no ejerce ninguna influencia en la difusi\u00f3n de aire.<\/li><\/ul>\n\n\n\n<p>La difusi\u00f3n por mezcla de aire es adecuada cuando:<\/p>\n\n\n\n<ul><li>Tengamos valores de carga sensible elevadas.<\/li><li>Tengamos que climatizar locales de baja altura.<\/li><li>Los contaminantes son m\u00e1s pesados que el aire ambiente.<\/li><li>En locales de gran volumen.<\/li><\/ul>\n\n\n\n<p>Entre las unidades terminales de impulsi\u00f3n distinguimos entre las que tiene gran importancia el efecto coanda y el alcance cr\u00edtico como son:<\/p>\n\n\n\n<ul><li>Rejas de impulsi\u00f3n colocadas en la pared.<\/li><li>Difusores de aros conc\u00e9ntricos.<\/li><li>Difusores lineales.<\/li><\/ul>\n\n\n\n<p>En las rejas para que haya efecto coanda impulsando aire fr\u00edo, se colocar\u00e1n a una distancia de 300 mm del techo, impulsando con una velocidad de \u00bb 2,5 m\/s y un Dt de -8\u00baC.<\/p>\n\n\n\n<p>En los difusores de aros conc\u00e9ntricos y lineales, para que haya efecto coanda, se colocaran enrasados con un falso techo para que la vena de aire fr\u00edo impulsada se adhiera al techo y penetre profundamente en el local.<\/p>\n\n\n\n<p>Por otra parte est\u00e1n las unidades terminales que por su inducci\u00f3n, el efecto coanda y el alcance cr\u00edtico no tienen influencia en la difusi\u00f3n y mezcla del aire como:<\/p>\n\n\n\n<ul><li>Difusores rotacionales<\/li><li>Toberas de alta inducci\u00f3n<\/li><\/ul>\n\n\n\n<p><strong>Difusi\u00f3n de aire por desplazamiento<\/strong><\/p>\n\n\n\n<p>En este sistema, el aire caliente contaminado asciende hasta el techo y se extrae por la parte superior del local, impulsando aire fr\u00edo reci\u00e9n filtrado a nivel del suelo.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"307\" height=\"172\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_3.png\" alt=\"\" class=\"wp-image-1848\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_3.png 307w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_3-300x168.png 300w\" sizes=\"(max-width: 307px) 100vw, 307px\" \/><\/figure><\/div>\n\n\n\n<p>La impulsi\u00f3n se realiza cerca del suelo con poca velocidad a temperatura inferior a la del ambiente. Este aire frio y limpio se distribuye de manera uniforme con poco movimiento por la totalidad de la superficie del suelo. De esta masa de aire fr\u00edo, junto a las fuentes de calor asciende el aire a medida que aumenta su temperatura al compensar la carga sensible que encuentra en su camino, arrastrando hac\u00eda la parte superior la contaminaci\u00f3n del ambiente.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"899\" height=\"469\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_4.png\" alt=\"\" class=\"wp-image-1849\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_4.png 899w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_4-300x157.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_4-768x401.png 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_4-500x261.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/11\/Antonio-Vega_4-800x417.png 800w\" sizes=\"(max-width: 899px) 100vw, 899px\" \/><\/figure><\/div>\n\n\n\n<p>Se generan temperaturas y niveles de contaminaci\u00f3n que aumentan con la altura del local, por lo que el retorno o extracci\u00f3n del aire se ha de hacer siempre por la parte m\u00e1s alta del local.<\/p>\n\n\n\n<p>Al contrario que en el sistema de mezcla de aire, en la difusi\u00f3n de aire por desplazamiento se busca la estratificaci\u00f3n del aire en altura, por lo que una de las limitaciones de este sistema es que se ha de impulsar con menor Dt que en el sistema de mezcla de aire, para tener un Dt entre 0,1 m, y 1,7 m sobre el suelo para personas de pie &lt; 3\u00baC, para que el porcentaje de personas incomodas sea aproximadamente del 5%.<\/p>\n\n\n\n<p>Resumiendo las caracter\u00edsticas de este sistema de difusi\u00f3n de aire son:<\/p>\n\n\n\n<ul><li>Es una forma de flujo de desplazamiento vertical en el que el aire se impulsa junto al suelo a una temperatura inferior a la del local, con baja velocidad y bajos \u00edndices de turbulencia sin que se mezcle el aire impulsado y el ambiente.<\/li><li>Las fuentes de calor originan corrientes de aire ascendentes que aumentan de velocidad con la altura del local en funci\u00f3n de la carga t\u00e9rmica de la fuente.<\/li><li>Se generan temperaturas y niveles de contaminaci\u00f3n del aire crecientes con la altura del local.<\/li><li>El aire se extrae por la parte superior del local.<\/li><li>Es adecuado en ambientes contaminados, cuando las part\u00edculas contaminantes son menos pesadas que el aire.<\/li><li>Se tienen niveles de confort y calidad de aire m\u00e1s altos que con el sistema por mezcla de aire.<\/li><li>Es un sistema recomendable para su utilizaci\u00f3n en teatros, auditorios, museos.<\/li><li>La instalaci\u00f3n puede funcionar m\u00e1s horas con enfriamiento gratuito (free-cooling), lo que representa un ahorro importante de energ\u00eda.<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Antonio Vegas Casado Miembro honor\u00edfico del Comit\u00e9 T\u00e9cnico de Atecyr Aunque todos los componentes que integran una instalaci\u00f3n de climatizaci\u00f3n son importantes, la difusi\u00f3n de aire tiene un papel fundamental. Con el aire que&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":1851,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[11],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/1844"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=1844"}],"version-history":[{"count":1,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/1844\/revisions"}],"predecessor-version":[{"id":1852,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/1844\/revisions\/1852"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/1851"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=1844"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=1844"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=1844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}