{"id":1400,"date":"2020-03-19T17:49:45","date_gmt":"2020-03-19T16:49:45","guid":{"rendered":"https:\/\/www.atecyr.org\/blog\/?p=1400"},"modified":"2021-06-11T10:11:36","modified_gmt":"2021-06-11T08:11:36","slug":"la-calidad-del-aire-interior-como-garantia-de-confort-para-las-personas-por-meritxell-junca-rodriguez","status":"publish","type":"post","link":"https:\/\/www.atecyr.org\/blog\/2020\/03\/19\/la-calidad-del-aire-interior-como-garantia-de-confort-para-las-personas-por-meritxell-junca-rodriguez\/","title":{"rendered":"La Calidad del Aire Interior como garant\u00eda de confort para las personas, por Meritxell Junc\u00e0 Rodr\u00edguez"},"content":{"rendered":"\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:16% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro.png\" alt=\"\" class=\"wp-image-1411 size-full\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro.png 800w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro-150x150.png 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro-300x300.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro-768x768.png 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro-500x500.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro-160x160.png 160w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/El-pulsometro-320x320.png 320w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:24px\"><strong> Meritxell Junc\u00e0 Rodr\u00edguez&nbsp;<\/strong><\/p>\n\n\n\n<p> Marketing Manager de TESTO Espa\u00f1a (TESTO Espa\u00f1a, Socio protector de Atecyr)<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>La concentraci\u00f3n de CO2 el protagonista para la Calidad de Aire<\/strong><\/p>\n\n\n\n<p>El contenido de CO\u2082 en el aire\npresente en interiores es la expresi\u00f3n directa de la intensidad de uso del\nrecinto. Por este motivo tambi\u00e9n es ideal como se\u00f1al de orientaci\u00f3n para otros\nrangos de regulaci\u00f3n tales como las dimensiones de las instalaciones de\nclimatizaci\u00f3n o para las instrucciones de ventilaci\u00f3n en recintos con\nventilaci\u00f3n natural como aulas de colegios o salas de reuniones, entre otros.<\/p>\n\n\n\n<p>En interiores con afluencia de personas, la concentraci\u00f3n de CO\u2082 depende fundamentalmente de los siguientes factores: <\/p>\n\n\n\n<p>\u2022\nCantidad de personas en el recinto, volumen del recinto<\/p>\n\n\n\n<p>\u2022\nActividad realizada por los usuarios en el recinto<\/p>\n\n\n\n<p>\u2022\nPeriodo de estancia de los usuarios del recinto<\/p>\n\n\n\n<p>\u2022\nProcesos de combusti\u00f3n en el recinto<\/p>\n\n\n\n<p>\u2022 Renovaci\u00f3n del aire o caudal volum\u00e9trico del aire exterior<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"660\" height=\"397\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T1.png\" alt=\"\" class=\"wp-image-1401\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T1.png 660w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T1-300x180.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T1-500x301.png 500w\" sizes=\"(max-width: 660px) 100vw, 660px\" \/><\/figure><\/div>\n\n\n\n<p>El\nCO<sub>2<\/sub> representa un valor de referencia para garantizar la calidad de\naire interior en diferentes entornos normativos. Con la entrada en vigor del\nReal Decreto 1027\/2007, de 20 de julio del 2017, por el que se aprueba el\nReglamento de Instalaciones T\u00e9rmicas en los Edificios, en adelante RITE, la\nconcentraci\u00f3n de CO<sub>2<\/sub> se determina como uno de los m\u00e9todos directos\npara garantizar las exigencias t\u00e9cnicas de bienestar e higiene que establece\neste reglamento.<\/p>\n\n\n\n<p>En el Reglamento se dispone unos niveles de calidad de aire interior seg\u00fan aplicaci\u00f3n del edificio tal y como recoge la tabla adjunta: <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"731\" height=\"324\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T2.png\" alt=\"\" class=\"wp-image-1402\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T2.png 731w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T2-300x133.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T2-500x222.png 500w\" sizes=\"(max-width: 731px) 100vw, 731px\" \/><\/figure><\/div>\n\n\n\n<p> Esta clasificaci\u00f3n define los \u00edndices de CO<sub>2<\/sub> permitidos para cada IDA. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"387\" height=\"146\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T3.png\" alt=\"\" class=\"wp-image-1403\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T3.png 387w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T3-300x113.png 300w\" sizes=\"(max-width: 387px) 100vw, 387px\" \/><\/figure><\/div>\n\n\n\n<p>La tabla indica el valor de la concentraci\u00f3n de CO<sub>2<\/sub> sobre el nivel de concentraci\u00f3n en el aire exterior. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T4-2.png\" alt=\"\" class=\"wp-image-1406\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T4-2.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T4-2-150x150.png 150w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T4-2-300x300.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T4-2-160x160.png 160w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T4-2-320x320.png 320w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>En este sentido, desde hace 150 a\u00f1os el qu\u00edmico e higienista alem\u00e1n Max von Pettenkofer resalt\u00f3 el hecho del \u00abaire viciado\u00bb durante una estancia prolongada en viviendas e instituciones acad\u00e9micas e identific\u00f3 el di\u00f3xido de carbono como un componente importante para la valoraci\u00f3n de la calidad del aire interior. <\/p>\n\n\n\n<p>Adem\u00e1s, defini\u00f3 como criterio el valor de referencia de CO\u2082 v\u00e1lido por cierto tiempo de 0,1 vol % (= 1000 ppm) en interiores, el llamado el n\u00famero de Pettenkofer. A partir de esta concentraci\u00f3n pueden presentarse malestares como dolor de cabeza y desconcentraci\u00f3n.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"1012\" height=\"742\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T5.png\" alt=\"\" class=\"wp-image-1407\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T5.png 1012w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T5-300x220.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T5-768x563.png 768w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T5-500x367.png 500w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T5-800x587.png 800w\" sizes=\"(max-width: 1012px) 100vw, 1012px\" \/><\/figure><\/div>\n\n\n\n<p>Referente a este \u00edndice\ntambi\u00e9n se actualizaron los valores de concentraciones m\u00e1ximas de contaminante referidas\na las partes por mill\u00f3n (ppm) de CO2 en el Orden FOM\/588\/2017, de 15 de junio,\npor la que se modifican el Documento B\u00e1sico DB-HE \u00abAhorro de energ\u00eda\u00bb y el\nDocumento B\u00e1sico DB-HS \u00abSalubridad\u00bb, del C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n,\naprobado por Real Decreto 314\/2006, de 17 de marzo.<\/p>\n\n\n\n<p>Concretamente en esta reciente\nmodificaci\u00f3n se refleja una bajada muy clara de los caudales de ventilaci\u00f3n y\nde la manera de calcularlos. Adem\u00e1s, se establece que en los locales habitables\nde las viviendas debe aportarse un caudal de aire exterior suficiente para\nconseguir que en cada local la concentraci\u00f3n media anual de CO2 sea menor que\n900 ppm y que el acumulado anual de CO2 que exceda 1.600 ppm sea menor que\n500.000 ppm\u00b7h.<\/p>\n\n\n\n<p>Entendiendo como Acumulado anual de CO2, como la magnitud que representa la relaci\u00f3n entre las concentraciones de CO2 alcanzadas por encima de un determinado valor (valor base) y el tiempo que se han mantenido a lo largo de un a\u00f1o. Puede calcularse como el sumatorio de las \u00e1reas (medidas en ppm\u00b7hora) contenidas entre la representaci\u00f3n de las concentraciones de CO2 en funci\u00f3n del tiempo y el valor base.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"624\" height=\"353\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T6.png\" alt=\"\" class=\"wp-image-1408\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T6.png 624w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T6-300x170.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T6-500x283.png 500w\" sizes=\"(max-width: 624px) 100vw, 624px\" \/><\/figure><\/div>\n\n\n\n<p><strong>S\u00edndrome del edificio enfermo.<\/strong><\/p>\n\n\n\n<p>El concepto \u00abS\u00edndrome del edificio enfermo\u00bb (SEE, del ingl\u00e9s\n\u201cSBS\u201d o \u201cSick Building Syndrome\u201d) se puede entender de dos maneras: por una\nparte, los edificios que enferman a los trabajadores presentes y, por otro\nlado, los mismos edificios se caracterizan como \u00abenfermos\u00bb.<\/p>\n\n\n\n<p>Generalmente, la causa del s\u00edndrome del edificio enfermo son la climatizaci\u00f3n o la falta de higiene del aire. La gama de s\u00edntomas es bastante amplia: irritaciones de los ojos, nariz y garganta; sequedad en mucosas y piel; cansancio mental; infecciones frecuentes de las v\u00edas respiratorias y tos; ronquera, disnea, picaz\u00f3n e hipersensibilidad no espec\u00edfica.<\/p>\n\n\n\n<p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nUn\nestudio norteamericano en edificios con sistemas de ventilaci\u00f3n y climatizaci\u00f3n\npudo comprobar de forma estad\u00edstica relaciones significativas y positivas entre\nmolestias tales como garganta seca e irritaciones de las mucosas y el aumento\nde las concentraciones de CO2 incluso en el rango de concentraciones por debajo\nde 1000 ppm.\n\n\n\n<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"660\" height=\"397\" src=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T7.png\" alt=\"\" class=\"wp-image-1409\" srcset=\"https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T7.png 660w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T7-300x180.png 300w, https:\/\/www.atecyr.org\/blog\/wp-content\/uploads\/2020\/03\/T7-500x301.png 500w\" sizes=\"(max-width: 660px) 100vw, 660px\" \/><\/figure><\/div>\n\n\n\n<p>Estudios m\u00e1s recientes indican\nque los costes para la eliminaci\u00f3n del problema en relaci\u00f3n con las condiciones\nambientales viciadas generalmente son m\u00e1s altos para el empleador, el\npropietario del edificio y la empresa que los costes de energ\u00eda del edificio en\ncuesti\u00f3n. Tambi\u00e9n se ha comprobado que una calidad adecuada de las condiciones\nambientales mejora el rendimiento general durante el trabajo y el estudio y\nreduce los d\u00edas de absentismo laboral.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Meritxell Junc\u00e0 Rodr\u00edguez&nbsp; Marketing Manager de TESTO Espa\u00f1a (TESTO Espa\u00f1a, Socio protector de Atecyr) La concentraci\u00f3n de CO2 el protagonista para la Calidad de Aire El contenido de CO\u2082 en el aire presente en&#46;&#46;&#46;<\/p>\n","protected":false},"author":3,"featured_media":1412,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[10],"tags":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/1400"}],"collection":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/comments?post=1400"}],"version-history":[{"count":4,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/1400\/revisions"}],"predecessor-version":[{"id":2021,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/posts\/1400\/revisions\/2021"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media\/1412"}],"wp:attachment":[{"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/media?parent=1400"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/categories?post=1400"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atecyr.org\/blog\/wp-json\/wp\/v2\/tags?post=1400"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}